Literature DB >> 3032502

Comparison of electron microscopy with three commercial tests for the detection of rotavirus in animal feces.

S M Goyal, R A Rademacher, K A Pomeroy.   

Abstract

Three commercial test kits were evaluated to detect the presence of rotavirus antigens in bovine, porcine, and turkey feces. Two of the assays, Rotalex (Medical Technology Corporation, Somerset, NJ) and Virogen-Rotatest (Wampole Labs, Cranbury, NJ) are latex agglutination tests (LA), while the third, Pathfinder (Kallestad, Austin, TX) is an enzyme immunoassay. The clinical usefulness of these assays was elevated by comparing their results with those of direct electron microscopy (EM). A total of 135, 92, and 211 samples of animal feces were tested by Rotalex, Virogen, and Pathfinder, respectively. All samples were examined by EM as a reference procedure. The overall agreement of the three commercial assays with EM was 53%, 66%, and 83% for Rotalex, Virogen, and Pathfinder, respectively. Based on these results, we consider Pathfinder as an attractive alternative to EM for the detection of rotavirus in animals. Of the two LA tests, Virogen was found to be a little more sensitive and specific.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3032502     DOI: 10.1016/0732-8893(87)90019-8

Source DB:  PubMed          Journal:  Diagn Microbiol Infect Dis        ISSN: 0732-8893            Impact factor:   2.803


  5 in total

1.  Latex test for rapid rotavirus diagnosis in calves.

Authors:  A Sukura; E Neuvonen
Journal:  Acta Vet Scand       Date:  1990       Impact factor: 1.695

2.  Evaluation of a human group a rotavirus assay for on-site detection of bovine rotavirus.

Authors:  Roger K Maes; Daniel L Grooms; Annabel G Wise; Cunqin Han; Valerie Ciesicki; Lora Hanson; Mary Lynne Vickers; Charles Kanitz; Robert Holland
Journal:  J Clin Microbiol       Date:  2003-01       Impact factor: 5.948

3.  Cold argon-oxygen plasma species oxidize and disintegrate capsid protein of feline calicivirus.

Authors:  Hamada A Aboubakr; Sunil K Mor; LeeAnn Higgins; Anibal Armien; Mohammed M Youssef; Peter J Bruggeman; Sagar M Goyal
Journal:  PLoS One       Date:  2018-03-22       Impact factor: 3.240

4.  Detection of viruses in used ventilation filters from two large public buildings.

Authors:  Sagar M Goyal; Senthilvelan Anantharaman; M A Ramakrishnan; Suchitra Sajja; Seung Won Kim; Nicholas J Stanley; James E Farnsworth; Thomas H Kuehn; Peter C Raynor
Journal:  Am J Infect Control       Date:  2011-05-06       Impact factor: 2.918

5.  Detection and molecular characterization of enteric viruses from poult enteritis syndrome in turkeys.

Authors:  N Jindal; D P Patnayak; Y Chander; A F Ziegler; S M Goyal
Journal:  Poult Sci       Date:  2010-02       Impact factor: 3.352

  5 in total