Literature DB >> 30324388

Intra-individual comparison of gadolinium-enhanced MRI using pseudo-golden-angle radial acquisition with gadoxetic acid-enhanced MRI for diagnosis of HCCs using LI-RADS.

Yoon-Chul Kim1, Ji Hye Min2, Young Kon Kim3, Soon Jin Lee4, Soohyun Ahn5, Eunju Kim6, Hans Peeters7.   

Abstract

OBJECTIVES: To determine the usefulness of extracellular contrast agent (ECA)-enhanced multiphasic liver magnetic resonance imaging (MRI) using a pseudo-golden-angle radial acquisition scheme by intra-individual comparison with gadoxetic acid-MRI (EOB-MRI) with regard to image quality and the diagnosis of hepatocellular carcinoma (HCC).
MATERIALS AND METHODS: This prospective study enrolled 15 patients with 18 HCCs who underwent EOB-MRI using a Cartesian approach and ECA-MRI using the pseudo-golden-angle radial acquisition scheme (free-breathing continuous data acquisition for 64 s following ECA injection, generating six images). Two reviewers evaluated the arterial and portal phases of each MRI for artifacts, organ sharpness, and conspicuity of intrahepatic vessels and the hepatic tumors. A Liver Imaging Reporting and Data System category was also assigned to each lesion.
RESULTS: There were no differences in the subjective image quality analysis between the arterial phases of two MRIs (p > 0.05). However, ghosting artifact was seen only in EOB-MRI (N = 3). Six HCCs showed different signal intensities in the arterial phase or portal phase between the two MRIs; five HCCs showed arterial hyperenhancement on ECA-MRI, but not on EOB-MRI. The capsule was observed in 15 HCCs on ECA-MRI and 6 HCCs on EOB-MRI. Five and one HCC were assigned as LR-5 and LR-4 with ECA-MRI and LR-4 and LR-3 with EOB-MRI, respectively.
CONCLUSION: Free-breathing ECA-enhanced multiphasic liver MRI using a pseudo-golden-angle radial acquisition was more sensitive in detecting arterial hyperenhancement of HCC than conventional EOB-MRI, and the image quality was acceptable. KEY POINTS: • The pseudo-golden-angle radial acquisition scheme can be applied to perform free-breathing multiphasic dynamic liver MRI. • Adopting the pseudo-golden-angle radial acquisition scheme can improve the detection of arterial enhancement of HCC. • The pseudo-golden-angle radial acquisition scheme enables motion-free liver MRI.

Entities:  

Keywords:  Artifacts; Carcinoma; Hepatocellular; Liver; Magnetic resonance imaging

Mesh:

Substances:

Year:  2018        PMID: 30324388     DOI: 10.1007/s00330-018-5771-x

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  4 in total

1.  Three dimensional radial echo planar imaging for functional MRI.

Authors:  Christoph A Rettenmeier; Danilo Maziero; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2021-08-19       Impact factor: 4.668

2.  Influence of dilution on arterial-phase artifacts and signal intensity on gadoxetic acid-enhanced liver MRI.

Authors:  Sarah Poetter-Lang; Gregor O Dovjak; Alina Messner; Raphael Ambros; Stephan H Polanec; Pascal A T Baltzer; Antonia Kristic; Alexander Herold; Jacqueline C Hodge; Michael Weber; Nina Bastati; Ahmed Ba-Ssalamah
Journal:  Eur Radiol       Date:  2022-07-27       Impact factor: 7.034

3.  Alternative approach of hepatocellular carcinoma surveillance: abbreviated MRI.

Authors:  Ryan L Brunsing; Kathryn J Fowler; Takeshi Yokoo; Guilherme Moura Cunha; Claude B Sirlin; Robert M Marks
Journal:  Hepatoma Res       Date:  2020-09-01

Review 4.  Diagnosis of Hepatocellular Carcinoma Using Gd-EOB-DTPA MR Imaging.

Authors:  Takamichi Murakami; Keitaro Sofue; Masatoshi Hori
Journal:  Magn Reson Med Sci       Date:  2021-08-21       Impact factor: 2.760

  4 in total