Literature DB >> 30321535

Effectiveness of artificial pancreas in the non-adult population: A systematic review and network meta-analysis.

Vasilios Karageorgiou1, Theodoros G Papaioannou2, Ioannis Bellos1, Krystallenia Alexandraki3, Nikolaos Tentolouris4, Christodoulos Stefanadis5, George P Chrousos6, Dimitrios Tousoulis1.   

Abstract

OBJECTIVE: Artificial pancreas is a technology that minimizes user input by bridging continuous glucose monitoring and insulin pump treatment, and has proven safety in the adult population. The purpose of this systematic review and meta-analysis is to evaluate the efficacy of closed-loop (CL) systems in the glycemic control of non-adult type 1 diabetes patients in both a pairwise and network meta-analysis (NMA) context and investigate various parameters potentially affecting the outcome.
METHODS: Literature was systematically searched using the MEDLINE (1966-2018), Scopus (2004-2018), Cochrane Central Register of Controlled Trials (CENTRAL) (1999-2018), Clinicaltrials.gov (2008-2018) and Google Scholar (2004-2018) databases. Studies comparing the glycemic control in CL (either single- or dual-hormone) with continuous subcutaneous insulin infusion (CSII) in people with diabetes (PWD) aged <18 years old were deemed eligible. The primary outcome analysis was conducted with regard to time spent in the target glycemic range. All outcomes were evaluated in NMA in order to investigate potential between-algorithm differences. Pairwise meta-analysis and meta-regression were performed using the RevMan 5.3 and Open Meta-Analyst software. For NMA, the package pcnetmetain R 3.5.1 was used.
RESULTS: The meta-analysis was based on 25 studies with a total of 504 PWD. The CL group was associated with significantly higher percentage of time spent in the target glycemic range (Mean (SD): 67.59% (SD: 8.07%) in the target range and OL PWD spending 55.77% (SD: 11.73%), MD: -11.97%, 95% CI [-18.40, -5.54%]) and with lower percentages of time in hyperglycemia (MD: 3.01%, 95% CI [1.68, 4.34%]) and hypoglycemia (MD: 0.67%, 95% CI [0.21, 1.13%]. Mean glucose was also decreased in the CL group (MD: 0.75 mmol/L, 95% CI [0.18-1.33]). The NMA arm of the study showed that the bihormonal modality was superior to other algorithms and standard treatment in lowering mean glucose and increasing time spent in the target range. The DiAs platform was superior to PID in controlling hypoglycemia and mean glucose. Time in target range and mean glucose were unaffected by the confounding factors tested.
CONCLUSIONS: The findings of this meta-analysis suggest that artificial pancreas systems are superior to the standard sensor-augmented pump treatment of type 1 diabetes mellitus in non-adult PWD. Between-algorithm differences are also addressed, implying a superiority of the bihormonal treatment modality. Future large-scale studies are needed in the field to verify these outcomes and to determine the optimal algorithm to be used in the clinical setting.
Copyright © 2018 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Artificial pancreas; Closed-loop; Diabetes mellitus; Meta-analysis; Pediatric

Mesh:

Substances:

Year:  2018        PMID: 30321535     DOI: 10.1016/j.metabol.2018.10.002

Source DB:  PubMed          Journal:  Metabolism        ISSN: 0026-0495            Impact factor:   8.694


  19 in total

1.  Six-Month Randomized, Multicenter Trial of Closed-Loop Control in Type 1 Diabetes.

Authors:  Sue A Brown; Boris P Kovatchev; Dan Raghinaru; John W Lum; Bruce A Buckingham; Yogish C Kudva; Lori M Laffel; Carol J Levy; Jordan E Pinsker; R Paul Wadwa; Eyal Dassau; Francis J Doyle; Stacey M Anderson; Mei Mei Church; Vikash Dadlani; Laya Ekhlaspour; Gregory P Forlenza; Elvira Isganaitis; David W Lam; Craig Kollman; Roy W Beck
Journal:  N Engl J Med       Date:  2019-10-16       Impact factor: 91.245

Review 2.  Artificial Pancreas: Current Progress and Future Outlook in the Treatment of Type 1 Diabetes.

Authors:  Rozana Ramli; Monika Reddy; Nick Oliver
Journal:  Drugs       Date:  2019-07       Impact factor: 9.546

3.  SPINA Carb: a simple mathematical model supporting fast in-vivo estimation of insulin sensitivity and beta cell function.

Authors:  Bernhard O Boehm; Nihal Thomas; Johannes W Dietrich; Riddhi Dasgupta; Shajith Anoop; Felix Jebasingh; Mathews E Kurian; Mercy Inbakumari
Journal:  Sci Rep       Date:  2022-10-21       Impact factor: 4.996

4.  Evening and overnight closed-loop control versus 24/7 continuous closed-loop control for type 1 diabetes: a randomised crossover trial.

Authors:  Boris P Kovatchev; Laura Kollar; Stacey M Anderson; Charlotte Barnett; Marc D Breton; Kelly Carr; Rachel Gildersleeve; Mary C Oliveri; Christian A Wakeman; Sue A Brown
Journal:  Lancet Digit Health       Date:  2020-01-03

5.  The Digital/Virtual Diabetes Clinic: The Future Is Now-Recommendations from an International Panel on Diabetes Digital Technologies Introduction.

Authors:  Moshe Phillip; Richard M Bergenstal; Kelly L Close; Thomas Danne; Satish K Garg; Lutz Heinemann; Irl B Hirsch; Boris P Kovatchev; Lori M Laffel; Viswanathan Mohan; Christopher G Parkin; Tadej Battelino
Journal:  Diabetes Technol Ther       Date:  2020-09-28       Impact factor: 6.118

Review 6.  Felix dies natalis, insulin… ceterum autem censeo "beta is better".

Authors:  Lorenzo Piemonti
Journal:  Acta Diabetol       Date:  2021-05-23       Impact factor: 4.280

7.  Clinical Management and Pump Parameter Adjustment of the Control-IQ Closed-Loop Control System: Results from a 6-Month, Multicenter, Randomized Clinical Trial.

Authors:  Grenye O'Malley; Laurel H Messer; Carol J Levy; Jordan E Pinsker; Gregory P Forlenza; Elvira Isganaitis; Yogish C Kudva; Laya Ekhlaspour; Dan Raghinaru; John Lum; Sue A Brown
Journal:  Diabetes Technol Ther       Date:  2021-04       Impact factor: 6.118

Review 8.  Time in Range for Closed-Loop Systems versus Standard of Care during Physical Exercise in People with Type 1 Diabetes: A Systematic Review and Meta-Analysis.

Authors:  Max L Eckstein; Benjamin Weilguni; Martin Tauschmann; Rebecca T Zimmer; Faisal Aziz; Harald Sourij; Othmar Moser
Journal:  J Clin Med       Date:  2021-05-31       Impact factor: 4.241

9.  Review of Automated Insulin Delivery Systems for Individuals with Type 1 Diabetes: Tailored Solutions for Subpopulations.

Authors:  Eleonora M Aiello; Sunil Deshpande; Basak Ozaslan; Kelilah L Wolkowicz; Eyal Dassau; Jordan E Pinsker; Francis J Doyle
Journal:  Curr Opin Biomed Eng       Date:  2021-06-18

10.  Intraperitoneal and subcutaneous glucagon delivery in anaesthetized pigs: effects on circulating glucagon and glucose levels.

Authors:  Marte Kierulf Åm; Ilze Dirnena-Fusini; Anders Lyngvi Fougner; Sven Magnus Carlsen; Sverre Christian Christiansen
Journal:  Sci Rep       Date:  2020-08-13       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.