Literature DB >> 30319890

Reflection artifact identification in photoacoustic imaging using multi-wavelength excitation.

Ho Nhu Y Nguyen1, Altaf Hussain1, Wiendelt Steenbergen1.   

Abstract

Photoacoustic imaging has been a focus of research for clinical applications owing to its ability for deep visualization with optical absorption contrast. However, there are various technical challenges remaining for this technique to find its place in clinics. One of the challenges is the occurrence of reflection artifacts. The reflection artifacts may lead to image misinterpretation. Here we propose a new method using multiple wavelengths for identifying and removing the reflection artifacts. By imaging the sample with multiple wavelengths, the spectral response of the features in the photoacoustic image is obtained. We assume that the spectral response of the reflection artifact is better correlated with the proper image feature of its corresponding absorber than with other features in the image. Based on this, the reflection artifacts can be identified and removed. Here, we experimentally demonstrated the potential of this method for real-time identification and correction of reflection artifacts in photoacoustic images in phantoms as well as in vivo using a handheld photoacoustic imaging probe.

Keywords:  (170.3880) Medical and biological imaging; (170.5120) Photoacoustic imaging

Year:  2018        PMID: 30319890      PMCID: PMC6179390          DOI: 10.1364/BOE.9.004613

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  22 in total

1.  Optical properties of fat emulsions.

Authors:  René Michels; Florian Foschum; Alwin Kienle
Journal:  Opt Express       Date:  2008-04-14       Impact factor: 3.894

2.  Reduction of background in optoacoustic image sequences obtained under tissue deformation.

Authors:  Michael Jaeger; Lea Siegenthaler; Michael Kitz; Martin Frenz
Journal:  J Biomed Opt       Date:  2009 Sep-Oct       Impact factor: 3.170

3.  Photoacoustic reflection artifact reduction using photoacoustic-guided focused ultrasound: comparison between plane-wave and element-by-element synthetic backpropagation approach.

Authors:  Mithun Kuniyil Ajith Singh; Michael Jaeger; Martin Frenz; Wiendelt Steenbergen
Journal:  Biomed Opt Express       Date:  2017-03-20       Impact factor: 3.732

4.  Photoacoustic-guided focused ultrasound for accurate visualization of brachytherapy seeds with the photoacoustic needle.

Authors:  Mithun Kuniyil Ajith Singh; Vinay Parameshwarappa; Ellen Hendriksen; Wiendelt Steenbergen; Srirang Manohar
Journal:  J Biomed Opt       Date:  2016-12-01       Impact factor: 3.170

5.  Photoacoustic clutter reduction by inversion of a linear scatter model using plane wave ultrasound measurements.

Authors:  Hans-Martin Schwab; Martin F Beckmann; Georg Schmitz
Journal:  Biomed Opt Express       Date:  2016-03-24       Impact factor: 3.732

6.  Non-invasive sentinel lymph node mapping and needle guidance using clinical handheld photoacoustic imaging system in small animal.

Authors:  Kathyayini Sivasubramanian; Vijitha Periyasamy; Manojit Pramanik
Journal:  J Biophotonics       Date:  2017-08-07       Impact factor: 3.207

7.  Hand-held, clinical dual mode ultrasound - photoacoustic imaging of rat urinary bladder and its applications.

Authors:  Kathyayini Sivasubramanian; Vijitha Periyasamy; Rhonnie Austria Dienzo; Manojit Pramanik
Journal:  J Biophotonics       Date:  2018-02-09       Impact factor: 3.207

8.  Visualization of tumor-related blood vessels in human breast by photoacoustic imaging system with a hemispherical detector array.

Authors:  M Toi; Y Asao; Y Matsumoto; H Sekiguchi; A Yoshikawa; M Takada; M Kataoka; T Endo; N Kawaguchi-Sakita; M Kawashima; E Fakhrejahani; S Kanao; I Yamaga; Y Nakayama; M Tokiwa; M Torii; T Yagi; T Sakurai; K Togashi; T Shiina
Journal:  Sci Rep       Date:  2017-02-07       Impact factor: 4.379

9.  The state of the art in breast imaging using the Twente Photoacoustic Mammoscope: results from 31 measurements on malignancies.

Authors:  Michelle Heijblom; Daniele Piras; Frank M van den Engh; Margreet van der Schaaf; Joost M Klaase; Wiendelt Steenbergen; Srirang Manohar
Journal:  Eur Radiol       Date:  2016-03-05       Impact factor: 5.315

10.  Rapid scanning wide-field clutter elimination in epi-optoacoustic imaging using comb LOVIT.

Authors:  Tigran Petrosyan; Maria Theodorou; Jeff Bamber; Martin Frenz; Michael Jaeger
Journal:  Photoacoustics       Date:  2018-02-19
View more
  4 in total

1.  Streak artifact suppression in photoacoustic computed tomography using adaptive back projection.

Authors:  Chuangjian Cai; Xuanhao Wang; Ke Si; Jun Qian; Jianwen Luo; Cheng Ma
Journal:  Biomed Opt Express       Date:  2019-08-26       Impact factor: 3.732

2.  Noninvasive staging of pressure ulcers using photoacoustic imaging.

Authors:  Ali Hariri; Fang Chen; Colman Moore; Jesse V Jokerst
Journal:  Wound Repair Regen       Date:  2019-07-26       Impact factor: 3.617

Review 3.  Review of consensus test methods in medical imaging and current practices in photoacoustic image quality assessment.

Authors:  Jorge Palma-Chavez; T Joshua Pfefer; Anant Agrawal; Jesse V Jokerst; William C Vogt
Journal:  J Biomed Opt       Date:  2021-09       Impact factor: 3.170

4.  Photoacoustic imaging for surgical guidance: Principles, applications, and outlook.

Authors:  Muyinatu A Lediju Bell
Journal:  J Appl Phys       Date:  2020-08-13       Impact factor: 2.546

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.