Impact of inter-observer variations in target volume delineation on dose volume indices for accelerated partial breast irradiation with multi-catheter interstitial brachytherapy.

Ritu Raj Upreti1, Ashwini Budrukkar2, Udita Upreti3, Tabassum Wadasadawala4, Shagun Misra2, Lavanya Gurram2, Rima Pathak2, Deepak D Deshpande5.   

Abstract

PURPOSE: To investigate dosimetric impact of inter-observer variation in clinical target volume(CTV) delineation for patients undergoing interstitial partial breast brachytherapy.
METHODS: Five radiation oncologists delineated CTV in twenty patients who underwent multi-catheter partial breast brachytherapy. Five treatment plans for each patient were graphically optimized for CTV of all observers and evaluated using coverage index(CI), external volume index(EI), overdose volume index(OI) and conformal index(COIN). In addition, volume enclosed by prescription isodose(V100), its spatial concordance(CIcommon), mean coverage of all CTVs with common volume of prescription dose(V100_common) and mean CTV coverage for all pairs of observer with common prescription volume of respective pairs(V100_pair) were also computed.
RESULTS: The mean ± standard deviation(SD) of CI and COIN ranged from 0.756 ± 0.076 to 0.840 ± 0.070 and 0.591 ± 0.090 to 0.673 ± 0.06 respectively. When a plan made for CTV of individual observer was evaluated on CTV of all observers, the maximum variations(ρ < 0.05) in the mean CI,COIN,OI and EI were 10.6%,11.4%,10.6% and 72.7% respectively. The observed mean ± SD of V100, CIcommon of V100, CTV coverage with V100_common and V100_pair was 160.7 ± 52.1, 0.70 ± 0.09, 73.1 ± 8.1% and 77.9 ± 7.3% respectively.
CONCLUSION: Inter-observer variation in delineation of CTV showed significant dosimetric impact with mean CTV coverage of 73.1% and 77.9% by common and paired prescription dose volume respectively among all observers.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Accelerated partial breast irradiation; Dose volume indices; Interobserver variation; Multicatheter interstitial brachytherapy

Mesh:

Year:  2018        PMID: 30318170     DOI: 10.1016/j.radonc.2018.06.029

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  2 in total

Review 1.  Effectiveness of different accelerated partial breast irradiation techniques for the treatment of breast cancer patients: Systematic review using indirect comparisons of randomized clinical trials.

Authors:  Gustavo Nader Marta; Jessica Barrett; Gustavo José Martiniano Porfirio; Ana Luiza Cabrera Martimbianco; José Luiz Barbosa Bevilacqua; Philip Poortmans; Rachel Riera
Journal:  Rep Pract Oncol Radiother       Date:  2019-02-15

2.  Coverage with dosimetric concordance index (CDCI): a tool for evaluating dosimetric impact of inter-observer target variability in brachytherapy.

Authors:  Ritu Raj Upreti; Ashwini Budrukkar; Udita Upreti; Tabassum Wadasadawala; Rima Pathak; Shagun Misra; Lavanya Gurrum; Rajesh A Kinhikar; Deepak D Deshpande
Journal:  J Contemp Brachytherapy       Date:  2020-04-08
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.