Masking Effect of Radiopharmaceutical Dose Extravasation During Injection on Myocardial Perfusion Defects During SPECT Myocardial Perfusion Imaging: A Potential Source of False Negative Result

Mohsen Qutbi1.   

Abstract

Proper interpretation of SPECT myocardial perfusion imaging (MPI) is primarily based on strict adherence to standard procedural protocols from patient preparation to image processing and display. Inadvertent faulty injection of the radiopharmaceutical and, consequently, dose extravasation during SPECT MPI is a more important issue than that in any other diagnostic scintigraphic procedure. As it can be considered as a major source of false negative result, clinician’s awareness of this problem during interpretation is of great importance. In some occasions, no local clinical signs or image findings may be available to the interpreter to be aware of dose extravasation to adopt a suitable approach. Herein, we present a case with dose extravasation during stress phase, which is repeated another day with the same protocol, and the potential effects of dose extravasation on SPECT myocardial perfusion images from different aspects and useful image findings as hints are provided.

Entities:  

Keywords:  Masking effect; radiopharmaceutical dose extravasation; myocardial perfusion defect; SPECT; false negative

Year:  2018        PMID: 30317853      PMCID: PMC6191731          DOI: 10.4274/mirt.88942

Source DB:  PubMed          Journal:  Mol Imaging Radionucl Ther        ISSN: 2146-1414


  4 in total

1.  Visualization in the ipsilateral lymph nodes secondary to extravasation of a bone-imaging agent in the left hand: a case report.

Authors:  W J Shih; J Collins; V Kiefer
Journal:  J Nucl Med Technol       Date:  2001-09

2.  The clinical importance of accurate measurement of injected doses for radionuclide myocardial perfusion imaging.

Authors:  Raymond Taillefer
Journal:  J Nucl Cardiol       Date:  2015-08-26       Impact factor: 5.952

Review 3.  Pitfalls and Limitations of Radionuclide and Hybrid Cardiac Imaging.

Authors:  Mark I Travin
Journal:  Semin Nucl Med       Date:  2015-09       Impact factor: 4.446

4.  Procedure guideline for myocardial perfusion imaging. Society of Nuclear Medicine.

Authors:  H W Strauss; D D Miller; M D Wittry; M D Cerqueira; E V Garcia; A S Iskandrian; H R Schelbert; F J Wackers
Journal:  J Nucl Med       Date:  1998-05       Impact factor: 10.057

  4 in total
  1 in total

1.  Practical Tools for Patient-specific Characterization and Dosimetry of Radiopharmaceutical Extravasation.

Authors:  Sean Wilson; Dustin Osborne; Misty Long; Josh Knowland; Darrell R Fisher
Journal:  Health Phys       Date:  2022-07-15       Impact factor: 2.922

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.