Literature DB >> 30315873

DVH-Based Inverse Planning Using Monte Carlo Dosimetry for LDR Prostate Brachytherapy.

Konstantinos A Mountris1, Dimitris Visvikis2, Julien Bert2.   

Abstract

PURPOSE: Inverse planning is an integral part of modern low-dose-rate brachytherapy. Current clinical planning systems do not exploit the total dose information and largely use the American Association of Physicists in Medicine TG-43 dosimetry formalism to ensure clinically acceptable planning times. Thus, suboptimal plans may be derived as a result of TG-43-related dose overestimation and nonconformity with dose distribution requirements. The purpose of this study was to propose an inverse planning approach that can improve planning quality by combining dose-volume information and precision without compromising the overall execution times. METHODS AND MATERIALS: The dose map was generated by accumulating precomputed Monte Carlo (MC) dose kernels for each candidate source implantation site. The MC computational burden was reduced by using graphics processing unit acceleration, allowing accurate dosimetry calculations to be performed in the intraoperative environment. The proposed dose-volume histogram (DVH) fast simulated annealing optimization algorithm was evaluated using clinical plans that were delivered to 18 patients who underwent low-dose-rate prostate brachytherapy.
RESULTS: Our method generated plans in 37.5 ± 3.2 seconds with similar prostate dose coverage, improved prostate dose homogeneity of up to 6.1%, and lower dose to the urethra of up to 4.0%.
CONCLUSIONS: A DVH-based optimization algorithm using MC dosimetry was developed. The inclusion of the DVH requirements allowed for increased control over the optimization outcome. The optimal plan's quality was further improved by considering tissue heterogeneity.
Copyright © 2018 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2018        PMID: 30315873     DOI: 10.1016/j.ijrobp.2018.09.041

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  2 in total

1.  An inverse planning simulated annealing algorithm with adaptive weight adjustment for LDR pancreatic brachytherapy.

Authors:  Ruijin Zhang; Zhiyong Yang; Shan Jiang; Xiaoling Yu; Erpeng Qi; Zeyang Zhou; Guobin Zhang
Journal:  Int J Comput Assist Radiol Surg       Date:  2021-08-28       Impact factor: 2.924

2.  Hybrid optimization based on non-coplanar needles for brachytherapy dose planning.

Authors:  Xiaodong Ma; Zhiyong Yang; Shan Jiang; Guobin Zhang; Bin Huo; Shude Chai
Journal:  J Contemp Brachytherapy       Date:  2019-06-28
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.