Literature DB >> 30314754

New use of 8-0 polypropylene suture for four-point scleral fixation of secondary intraocular lenses.

Thomas John1, Sean Tighe1, Omar Hashem1, Hosam Sheha2.   

Abstract

We describe 4-point scleral fixation of a posterior chamber intraocular lens (PC IOL) using 8-0 polypropylene (Prolene) sutures, without the handshake technique. First, 4 sclerotomy sites are marked 2.5 mm from the limbus, and 2 scleral grooves are created in between. Two sets of 8-0 polypropylene sutures are then passed through the IOL haptics. The PC IOL is inserted behind the iris, and the sutures are pulled ab interno and tightened for optimum IOL centration. The sutures and exposed knots are imbedded within the scleral groove and sealed with fibrin glue. This 4-point scleral fixation technique was performed uneventfully in 9 cases (4 men, 5 women; mean age 71.4 years ± 12.2 [SD]) and the PC IOL was stable for 10 months (range 8 months to 1 year) with no signs of IOL subluxation, dislocation, tilt, or suture-related complications such as erosion or infection.
Copyright © 2018 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 30314754     DOI: 10.1016/j.jcrs.2018.08.008

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  7 in total

1.  Late dislocation of the capsular bag-intraocular lens-modified capsular tension ring complex after knotless transscleral suturing using 9-0 polypropylene.

Authors:  Natalia S Anisimova; Lisa B Arbisser; Natalya F Shilova; Roman V Kirtaev; Daria A Dibina; Boris E Malyugin
Journal:  Digit J Ophthalmol       Date:  2020-06-26

2.  Flanged intraocular lens fixation via 27-gauge trocars using a double-needle technique decreases surgical wounds without losing its therapeutic effect.

Authors:  Hiroto Ishikawa; Hisashi Fukuyama; Yuki Komuku; Takashi Araki; Fumi Gomi
Journal:  Acta Ophthalmol       Date:  2019-11-17       Impact factor: 3.761

3.  Novel use of an adjustable single 8-0 polypropylene suture of scleral fixation without conjunctival dissection.

Authors:  Bin Mo; Song-Feng Li
Journal:  BMC Ophthalmol       Date:  2020-07-25       Impact factor: 2.209

4.  Intrascleral Suture Anchoring: A Flapless/Grooveless Four-Point Intraocular Lens Fixation Technique.

Authors:  Xin Hu; Bo Zhao; Haiying Jin
Journal:  J Ophthalmol       Date:  2020-12-01       Impact factor: 1.909

5.  Scleral Fixation of a Hydrophobic Acrylic Intraocular Lens with Eyelets Using 8-0 Polypropylene Suture.

Authors:  Do Wook Kim; Sung Chul Lee; Ji Hwan Lee
Journal:  Korean J Ophthalmol       Date:  2021-11-08

6.  A modified intrascleral intraocular lens fixation technique with fewer anterior segment manipulations: 27-gauge needle-guided procedure with built-in 8-0 absorbable sutures.

Authors:  Yuan Yang; Teng-Teng Yao; Ya-Li Zhou; Yi-Xiao Wang; Zhao-Yang Wang
Journal:  BMC Ophthalmol       Date:  2019-11-21       Impact factor: 2.209

7.  Intraocular Suture Looping Technique for Flapless Four-Point Refixation of Dislocated Intraocular Lenses.

Authors:  Xin Hu; Bo Zhao; Haiying Jin
Journal:  J Ophthalmol       Date:  2021-02-08       Impact factor: 1.909

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.