Literature DB >> 30312918

Effects of chlorination/chlorine dioxide disinfection on biofilm bacterial community and corrosion process in a reclaimed water distribution system.

Haiya Zhang1, Yimei Tian2, Mengxin Kang3, Chao Chen4, Yarong Song5, Han Li6.   

Abstract

In this work, reclaimed water treated with sodium hypochlorite (NaClO) or chlorine dioxide (ClO2) at 1, 2, and 4 mg/L was operated successively for 30 days respectively, in annular reactors with new cast iron coupons, corresponding to stages I (days 0-30), II (days 31-60), and III (days 61-90). The Illumina HiSeq 2500 sequencing platform was used to analyze the bacterial community composition, scanning electron microscopy and X-ray diffraction analyses were conducted to characterize corrosion scales, and the weight loss method was served to determine the general corrosion rate. Results reveal the precise disinfection effect on biofilm bacteria to be dose dependent and species specific. In stage I, disinfection caused a reduction in the number of operational taxonomic units, but, had little effect on biofilm composition. In stage II, NaClO and ClO2 induced a reduction of Proteobacteria proportion, but increased the dominance of Firmicutes; the diminished Proteobacteria in NaClO test mainly included Gammaproteobacteria, while, that in ClO2 test mainly included the Gammaproteobacteria and Betaproteobacteria. In stage III, Firmicutes presented a certain resistance to NaClO and ClO2 as the accumulation of corrosion scales. Results also indicated that disinfection enhanced the corrosion process, and the promoting effect of ClO2 was more pronounced than that of NaClO. Moreover, this promoting effect was more obvious in stage I than that in the latter two stages. The strong oxidization effect associated with disinfection in stage I was the dominant factor promoting corrosion, whereas, the bacterial community also played a crucial role in stages II and III.
Copyright © 2018 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Bacterial community; Cast iron; Corrosion process; Disinfection; Reclaimed water

Mesh:

Substances:

Year:  2018        PMID: 30312918     DOI: 10.1016/j.chemosphere.2018.09.181

Source DB:  PubMed          Journal:  Chemosphere        ISSN: 0045-6535            Impact factor:   7.086


  4 in total

Review 1.  Microbial diversity in full-scale water supply systems through sequencing technology: a review.

Authors:  Wei Zhou; Weiying Li; Jiping Chen; Yu Zhou; Zhongqing Wei; Longcong Gong
Journal:  RSC Adv       Date:  2021-07-22       Impact factor: 4.036

2.  Chloride corrosion behavior on heating pipeline made by AISI 304 and 316 in reclaimed water.

Authors:  Xi Chen; Hongyan Liu; Xiang Sun; Botao Zan; Meisheng Liang
Journal:  RSC Adv       Date:  2021-12-02       Impact factor: 3.361

3.  Plasma Sterilization Effectively Reduces Bacterial Contamination in Dental Unit Waterlines.

Authors:  Sarocha Noopan; Phattranit Unchui; Supitcha Techotinnakorn; Ruchanee Salingcarnboriboon Ampornaramveth
Journal:  Int J Dent       Date:  2019-07-30

4.  Characteristics of water quality and bacterial communities in three water supply pipelines.

Authors:  Dongpo Liu; Juntao Jin; Sichen Liang; Jinsong Zhang
Journal:  RSC Adv       Date:  2019-01-30       Impact factor: 3.361

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.