Improved Dose Conformity for Adjacent Targets: A Novel Planning Technique for Gamma Knife Stereotactic Radiosurgery.

Qianyi Xu1, Jinyu Xue2, Gregory Kubicek3, David Mulvihill3, Steven Oh3, Warren Goldman4, Alan Turtz5, Leonard Kim3.   

Abstract

Purpose In the current Gamma Knife (GK) planning system (GammaPlan, version 10.2, Elekta AB, Stockholm, Sweden), multiple adjacent brain metastasis (BMs) had to be planned sequentially if BMs were drawn separately, leading to less conformal target dose in the composite plan due to inter-target dose contribution and fine-tuning of the shots being quite tedious. We proposed a method to improve target dose conformality and planning efficiency for such cases. Methods and Materials Fifteen patients with multiple BMs treated on the Leksell GK Perfexion system were retrospectively replanned in the Institutional Review Board (IRB) approved study. The recruitment criterion was all the BMs should be entirely encompassed within the maximum dose grid allowed in the GammaPlan. The BMs were first planned sequentially as routine clinic cases. The contours of the BMs were then exported to the VelocityAI (Varian, CA, USA) to generate a composite contour after a union operation, and all the BMs were planned again simultaneously using this composite contour in the GammaPlan. The inverse planning (IP) was employed in both methods with the same treatment time allowed for a fair plan comparison. Dose evaluation was performed in the VelocityAI with all planning magnetic resonance (MR) images, structure set and dose were exported to the VelocityAI. The dosimetery parameters, including conformality index (CI), V20Gy, V16Gy, V12Gy, and V5Gy, were compared between the two methods. Results The planning results from both methods were reviewed qualitatively and quantitatively. The proposed method exhibited superior CI, except for an outlier case with very tiny BMs. The mean and standard deviation (std.) of the Paddick CI for all patients were 0.76±0.11 for the proposed method, comparing to 0.69±0.13 for the sequential method. The V20Gy, V16Gy, V12Gy, and V5Gy for the proposed method were 10.9±0.9%, 9.5±10.2%, 6.2±16.4% and 3.3±21.8%, all lower than those from the sequential method. Conclusions The proposed method showed improved target dose conformality for all cases except for very tiny BMs. Planning efficiency is considerably better with the combined target technique. The improved dose conformality will be beneficial to patients in long term with lowered risk of radiation necrosis after GK stereotactic radiosurgery (SRS).

Entities:  

Keywords:  gamma knife; gammaplan; inverse planning; stereotactic radiosurgery (srs)

Year:  2018        PMID: 30310763      PMCID: PMC6168383          DOI: 10.7759/cureus.3057

Source DB:  PubMed          Journal:  Cureus        ISSN: 2168-8184


  8 in total

1.  Automated Gamma Knife dose planning using polygon clipping and adaptive simulated annealing.

Authors:  G S Leichtman; A L Aita; H W Goldman
Journal:  Med Phys       Date:  2000-01       Impact factor: 4.071

2.  Real-time inverse planning for Gamma Knife radiosurgery.

Authors:  Q Jackie Wu; Vira Chankong; Suradet Jitprapaikulsarn; Barry W Wessels; Douglas B Einstein; Boonyanit Mathayomchan; Timothy J Kinsella
Journal:  Med Phys       Date:  2003-11       Impact factor: 4.071

3.  Plug pattern optimization for gamma knife radiosurgery treatment planning.

Authors:  Pengpeng Zhang; Jackie Wu; David Dean; Lei Xing; Jinyue Xue; Robert Maciunas; Claudio Sibata
Journal:  Int J Radiat Oncol Biol Phys       Date:  2003-02-01       Impact factor: 7.038

4.  Automated gamma knife radiosurgery treatment planning with image registration, data-mining, and Nelder-Mead simplex optimization.

Authors:  Kuan J Lee; David C Barber; Lee Walton
Journal:  Med Phys       Date:  2006-07       Impact factor: 4.071

5.  A simple dose gradient measurement tool to complement the conformity index.

Authors:  Ian Paddick; Bodo Lippitz
Journal:  J Neurosurg       Date:  2006-12       Impact factor: 5.115

6.  Leksell GammaPlan version 10.0 preview: performance of the new inverse treatment planning algorithm applied to Gamma Knife surgery for pituitary adenoma.

Authors:  David J Schlesinger; Faisal T Sayer; Chun-Po Yen; Jason P Sheehan
Journal:  J Neurosurg       Date:  2010-12       Impact factor: 5.115

7.  Stereotactic Radiosurgery for Poor Performance Status Patients.

Authors:  Gregory J Kubicek; Alan Turtz; Jinyu Xue; Ashish Patel; Gregory Richards; Tamara LaCouture; Louis Cappelli; Tim Diestelkamp; Piya Saraiya; Anne Bexon; Nati Lerman; Howard Warren Goldman
Journal:  Int J Radiat Oncol Biol Phys       Date:  2016-02-16       Impact factor: 7.038

8.  Dynamic gamma knife radiosurgery.

Authors:  Shuang Luan; Nathan Swanson; Zhe Chen; Lijun Ma
Journal:  Phys Med Biol       Date:  2009-02-19       Impact factor: 3.609

  8 in total
  1 in total

1.  Whole Brain Irradiation or Stereotactic RadioSurgery for five or more brain metastases (WHOBI-STER): A prospective comparative study of neurocognitive outcomes, level of autonomy in daily activities and quality of life.

Authors:  Gianluca Ferini; Anna Viola; Vito Valenti; Antonella Tripoli; Laura Molino; Valentina Anna Marchese; Salvatore Ivan Illari; Giuseppina Rita Borzì; Angela Prestifilippo; Giuseppe Emmanuele Umana; Emanuele Martorana; Gianluca Mortellaro; Giuseppe Ferrera; Alberto Cacciola; Sara Lillo; Antonio Pontoriero; Stefano Pergolizzi; Silvana Parisi
Journal:  Clin Transl Radiat Oncol       Date:  2021-12-02
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.