Samarium-153 has been standardized by 4 pi beta liquid-scintillation counting, with an uncertainty of 0.4%. The probability per decay for the 103.2-keV gamma ray was measured, using two germanium detectors, to be 0.298 +/- 0.004. The half life, based on liquid-scintillation measurements over 6.4 half lives and pressurized-ionization-chamber measurements over four half lives, was found to be 46.27 +/- 0.02 h. The uncertainties given are one estimated standard deviation (of the mean when applicable) for random and non-random components.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3030966     DOI: 10.1016/0883-2889(87)90232-2

Source DB:  PubMed          Journal:  Int J Rad Appl Instrum A        ISSN: 0883-2889


  2 in total

Review 1.  Samarium 153Sm lexidronam.

Authors:  H M Lamb; D Faulds
Journal:  Drugs Aging       Date:  1997-11       Impact factor: 3.923

2.  Samarium-153 EDTMP therapy of disseminated skeletal metastasis.

Authors:  J H Turner; A A Martindale; P Sorby; E L Hetherington; R F Fleay; R F Hoffman; P G Claringbold
Journal:  Eur J Nucl Med       Date:  1989