Literature DB >> 30307716

Marginal soft tissue stability around conical abutments inserted with the one abutment-one time protocol after 5 years of prosthetic loading.

Luigi Canullo1, Paolo Pesce2, Mauro Tronchi3, Joseph Fiorellini4, Yoshiyuki Amari5, David Penarrocha6.   

Abstract

BACKGROUND: Soft tissue stability is crucial to obtain and maintain optimal esthetic results.
PURPOSE: This study aimed to investigate, over 5 years, the soft tissue response using a conical abutment together with the "one-abutment one-time" (OA-OT) protocol in the restoration of implants inserted in the anterior esthetic area.
MATERIAL AND METHODS: From January 2011 to January 2012, all consecutive patients requiring an implant n the maxillary area between canines were enrolled. After submerged healing and osseointegration, a definitive abutment with a provisional crown was inserted. After 1 month, the definitive crown was delivered (Tdef). Analog impressions were taken before tooth extraction (T0), at implant insertion Timpl, and Tdef, and at 12 months (T1) and 60 months (T5). Casts were scanned and superimposed using a dedicated software. Differences in vertical height of soft tissue margins between the digitized model casts were calculated and paired sample t test was conducted to compare results. To detect the potential role of biotype, groups (thick vs. thin) were compared by analysis of variance with general linear model.
RESULTS: Twenty-five patients were enrolled. Three patients dropped out. At the 60-month, 22 patients (12 men and 10 women with mean age of 68.3 ± 11 years) concluded the study follow-up. Horizontal changes demonstrated gain of 1.06 mm at Timpl, 0.94 mm at Tdef, 0.92 mm at T1 and 0.97 mm at T5 compared to T0. Vertical changes demonstrated gain of 0.84 mm at Timpl, 0.11 mm at Tdef, 0.29 mm at T1 and 0.59 mm at T5 compared to T0. The analysis of variance showed a significant better performance of thick biotype in soft tissue horizontal width (P = .022). No statistical differences were noticed for vertical width (P = .111).
CONCLUSIONS: The use of a conical abutment together with the OA-OT approach allowed longitudinal stable soft tissue dimensions.
© 2018 Wiley Periodicals, Inc.

Entities:  

Keywords:  conical abutments; long-term; one-abutment-one-time; platform switching; soft tissue; soft tissue biotype

Mesh:

Year:  2018        PMID: 30307716     DOI: 10.1111/cid.12683

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  4 in total

1.  Evaluation of residual contamination on reused healing abutments.

Authors:  Sezgi Cinel Sahin; Kadriye Ayca Dere
Journal:  Clin Oral Investig       Date:  2021-03-25       Impact factor: 3.573

2.  A Novel Full-Digital Protocol (SCAN-PLAN-MAKE-DONE®) for the Design and Fabrication of Implant-Supported Monolithic Translucent Zirconia Crowns Cemented on Customized Hybrid Abutments: A Retrospective Clinical Study on 25 Patients.

Authors:  Francesco Mangano; Bidzina Margiani; Oleg Admakin
Journal:  Int J Environ Res Public Health       Date:  2019-01-24       Impact factor: 3.390

3.  Comparative evaluation of peri-implant tissues in definitive and repeated abutment replacements: A randomized clinical trial.

Authors:  Prachi Rajendra Rathi; Rajashri Abhay Kolte; Abhay Pandurang Kolte
Journal:  J Indian Soc Periodontol       Date:  2022-01-01

4.  Influence of Implant Thread Morphology on Primary Stability: A Prospective Clinical Study.

Authors:  Maria Menini; Francesco Bagnasco; Ivan Calimodio; Nicolò Di Tullio; Francesca Delucchi; Domenico Baldi; Francesco Pera
Journal:  Biomed Res Int       Date:  2020-08-05       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.