Literature DB >> 30302968

Holmium-YAG laser: impact of pulse energy and frequency on local fluid temperature in an in-vitro obstructed kidney calyx model.

Michael W Sourial1, Joshua Ebel1, Nathaly Francois1, Geoffrey N Box1, Bodo E Knudsen1.   

Abstract

During laser lithotripsy, energy is transmitted to both the stone and the surrounding fluid. As the energy is delivered, the temperature will rise. Temperatures ≥60  °  C can cause protein denaturation. The objective of this study is to determine the time it takes from body temperature (37°C) to 60°C at various laser power settings. A Flexiva TracTip 200 optical fiber was submerged alongside a negative temperature coefficient-type thermistor in 4 mL of saline in a glass test tube. A Lumenis VersaPulse Powersuite 100-W holmium:yttrium aluminum garnet laser was activated at 0.2- to 1.5-J pulse energies, 6- to 50-Hz frequencies, and 2- to 22.5-W average power. Temperature readings were recorded every second from 37°C until 60°C. Time and heating rate were measured. The procedure was repeated three times for each setting. Average time from 37°C to 60°C for settings (1) 0.2 J/50 Hz, (2) 0.6 J/6 Hz, (3) 1 J/10 Hz, and (4) 1.5 J/10 Hz was 60.3, 172.7, 58, and 43.3 s, respectively. Time from 37°C to 60°C decreased as frequency increased for every given pulse energy. Average heating rate increased proportionally to power from 0.06°C/s at 2 W to 0.74°C/s at 22.5 W. During laser lithotripsy, there is a rapid increase in the temperature of its surrounding fluid and temperatures ≥60  °  C may be reached. This could have local tissue effects and some caution with higher power settings should be employed especially where irrigation is limited. Further studies incorporating irrigation and live tissue models may aid to further define the risks. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

Entities:  

Keywords:  calculi; laser; lithotripsy; protein denaturation; temperature

Mesh:

Year:  2018        PMID: 30302968     DOI: 10.1117/1.JBO.23.10.105002

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  3 in total

1.  Temperature profiles of calyceal irrigation fluids during flexible ureteroscopic Ho:YAG laser lithotripsy.

Authors:  Jingfei Teng; Yi Wang; Zhuomin Jia; Yawei Guan; Weiwei Fei; Xing Ai
Journal:  Int Urol Nephrol       Date:  2020-09-28       Impact factor: 2.370

2.  Laser operator duty cycle effect on temperature and thermal dose: in-vitro study.

Authors:  Marne M Louters; Julie J Dau; Timothy L Hall; Khurshid R Ghani; William W Roberts
Journal:  World J Urol       Date:  2022-02-27       Impact factor: 4.226

3.  Patterns of Laser Activation During Ureteroscopic Lithotripsy: Effects on Caliceal Fluid Temperature and Thermal Dose.

Authors:  Ali H Aldoukhi; Julie J Dau; Sami E Majdalany; Timothy L Hall; Khurshid R Ghani; John M Hollingsworth; Sapan N Ambani; Casey A Dauw; William W Roberts
Journal:  J Endourol       Date:  2021-02-03       Impact factor: 2.619

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.