Literature DB >> 30302524

Transcoronary pacing : Reliability during myocardial ischemia and after implantation of a coronary stent.

K M Heinroth1, S Unverzagt2, D Mahnkopf3, R Prondzinsky4.   

Abstract

BACKGROUND: Transcoronary pacing is a useful therapeutic option for the treatment of unheralded bradycardias in the setting of percutaneous coronary interventions (PCI).
OBJECTIVES: In the present study, we investigated the influence of stent implantation and transient myocardial ischemia on the feasibility of transcoronary pacing in a porcine model.
METHODS: 7 adult pigs underwent a percutaneous coronary intervention with implantation of a coronary stent under general anaesthesia in an animal catheterization laboratory. Transcoronary pacing was established by using a standard guidewire isolated with an angioplasty balloon positioned in the periphery of the right coronary artery serving as the cathode. As the indifferent anode, a skin patch electrode at the back of the animal was used. The reliability of transcoronary pacing was assessed by measurement of threshold and impedance data and the magnitude of the epicardial electrogram at baseline, after implantation of a coronary stent and finally during myocardial ischemia.
RESULTS: Effective transcoronary pacing could be demonstrated in all cases with the standard unipolar transcoronary pacing setup yielding a low pacing threshold at baseline of 1.3 ± 0.8 V with an impedance of 283 ± 67 Ω. Implantation of a coronary stent did not influence the pacing threshold (1.0 ± 0.4 V) and impedance (262 ± 63 Ω). Acute myocardial ischemia lead to a significant but clinically nonrelevant increase of the pacing threshold to 2.0 ± 0.6 V and a drop in pacing impedance (137 ± 39 Ω).
CONCLUSIONS: Transcoronary pacing in the animal model is not affected by implantation of a coronary stent in the same vessel used for pacing. Despite a significant increase in pacing threshold, the transcoronary pacing approach is reliable in acute myocardial ischemia during a percutaneous coronary intervention.

Entities:  

Keywords:  Bradycardia; Coronary artery disease; Guidewire; Myocardial infarction; Temporary pacing

Year:  2018        PMID: 30302524     DOI: 10.1007/s00063-018-0492-0

Source DB:  PubMed          Journal:  Med Klin Intensivmed Notfmed        ISSN: 2193-6218            Impact factor:   0.840


  20 in total

1.  Left ventricular pacing for bradycardia in the cardiac catheterization laboratory.

Authors:  Bernhard Meier
Journal:  Catheter Cardiovasc Interv       Date:  2004-05       Impact factor: 2.692

2.  Surgical treatment for right ventricular perforation caused by transvenous pacing electrodes: a report of three cases.

Authors:  M Asano; A Mishima; T Ishii; Y Takeuchi; Y Suzuki; T Manabe
Journal:  Surg Today       Date:  1996       Impact factor: 2.549

3.  The double guidewire approach for transcoronary pacing in a porcine model.

Authors:  K M Heinroth; S Unverzagt; D Mahnkopf; S Frantz; R Prondzinsky
Journal:  Med Klin Intensivmed Notfmed       Date:  2016-11-23       Impact factor: 0.840

4.  Coronary pacing during percutaneous transluminal coronary angioplasty.

Authors:  B Meier; W Rutishauser
Journal:  Circulation       Date:  1985-03       Impact factor: 29.690

5.  [Emergency cardiac pacing via a coronary vessel during percutaneous coronary angioplasty].

Authors:  P Chatelain; B Meier; J Bélenger; J P Killisch; J N Cox; W Rutishauser
Journal:  Arch Mal Coeur Vaiss       Date:  1985-10

6.  Transcoronary cardiac pacing during myocardial ischemia.

Authors:  J R Laird; R Hull; K C Stajduhar; L T Weston; W Kufs; D C Wortham
Journal:  Cathet Cardiovasc Diagn       Date:  1993-10

7.  Percutaneous transluminal coronary angioplasty: report of complications from the National Heart, Lung, and Blood Institute PTCA Registry.

Authors:  G Dorros; M J Cowley; J Simpson; L G Bentivoglio; P C Block; M Bourassa; K Detre; A J Gosselin; A R Grüntzig; S F Kelsey; K M Kent; M B Mock; S M Mullin; R K Myler; E R Passamani; S H Stertzer; D O Williams
Journal:  Circulation       Date:  1983-04       Impact factor: 29.690

8.  Incications and complications of invasive diagnostic procedures and percutaneous coronary interventions in the year 2003. Results of the quality control registry of the Arbeitsgemeinschaft Leitende Kardiologische Krankenhausarzte (ALKK).

Authors:  U Zeymer; R Zahn; M Hochadel; T Bonzel; M Weber; M Gottwik; U Tebbe; J Senges
Journal:  Z Kardiol       Date:  2005-06

9.  Ventricular tachyarrhythmia initiation in a canine model of recent myocardial infarction. Comparison of unipolar cathodal, anodal and bipolar stimulation.

Authors:  O J Ohm; H Mitamura; E L Michelson; C Sauermelch; L S Dreifus
Journal:  Cardiology       Date:  1987       Impact factor: 1.869

10.  Temporary pacemaker use during coronary arteriography.

Authors:  I C Gilchrist; A Cameron
Journal:  Am J Cardiol       Date:  1987-11-01       Impact factor: 2.778

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.