Literature DB >> 30302442

Accuracy of computerized and conventional impression-making procedures for multiple straight and tilted dental implants.

Aiste Gintaute, Nikolaos Papatriantafyllou, Meshaal Aljehani, Wael Att.   

Abstract

PURPOSE: To compare the accuracy of implant impressions using computer-aided impression-making technology and a conventional approach in a standardized setting in vitro, and to verify the effect of implant angulation (40 to 45 degrees) on the accuracy of digital and conventional impression-making procedures.
MATERIALS AND METHODS: Four different edentulous mandibular reference models (RMs) were manufactured. Two straight (RM1); four straight (RM2); two straight and two tilted (RM3); and six straight (RM4) dental implants were placed, simulating four different clinical scenarios. The computer-aided impressions (n = 5 for each RM) were made using an intraoral scanner (IOS) (True Definition, 3M ESPE). Polyether (n = 5 for each RM) and vinyl polysiloxane (n = 5 for each RM) impression materials were utilized for the conventional approach. The collected data were analyzed in terms of trueness. The statistical analysis was performed using one-way analysis of variance (ANOVA).
RESULTS: The overall differences of interimplant distance, identified in mean values, were statistically significant among the different impression-making groups in RM1, RM3, and RM4. The data analyses of overall interimplant angle deviations yielded statistically significant differences in all four RMs. However, the deviations obtained with both impression-making approaches did not exceed an interimplant distance threshold of 100 µm, and an interimplant angle of 0.5 degrees, which seems to be clinically acceptable.
CONCLUSION: Within the limits of this in vitro study, the accuracy of the computer-aided and conventional impression-making approaches for straight and tilted dental implants was comparable, and might be clinically considered for full-arch, multiple-implant restorations. However, further clinical studies are required to verify the feasibility of different IOSs (with and without scanning powder application), different implant systems, and multiple implant configurations.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 30302442

Source DB:  PubMed          Journal:  Int J Esthet Dent


  8 in total

1.  Conventional versus Digital Impressions for Full Arch Screw-Retained Maxillary Rehabilitations: A Randomized Clinical Trial.

Authors:  Paolo Cappare; Gianpaolo Sannino; Margherita Minoli; Pietro Montemezzi; Francesco Ferrini
Journal:  Int J Environ Res Public Health       Date:  2019-03-07       Impact factor: 3.390

Review 2.  The direct digital workflow in fixed implant prosthodontics: a narrative review.

Authors:  George Michelinakis; Dimitrios Apostolakis; Phophi Kamposiora; George Papavasiliou; Mutlu Özcan
Journal:  BMC Oral Health       Date:  2021-01-21       Impact factor: 2.757

Review 3.  Accuracy of Digital Dental Implants Impression Taking with Intraoral Scanners Compared with Conventional Impression Techniques: A Systematic Review of In Vitro Studies.

Authors:  María Isabel Albanchez-González; Jorge Cortés-Bretón Brinkmann; Jesús Peláez-Rico; Carlos López-Suárez; Verónica Rodríguez-Alonso; María Jesús Suárez-García
Journal:  Int J Environ Res Public Health       Date:  2022-02-11       Impact factor: 3.390

4.  Trueness of digital implant impressions based on implant angulation and scan body materials.

Authors:  Jae-Hyun Lee; Jae-Hwi Bae; Su Young Lee
Journal:  Sci Rep       Date:  2021-11-08       Impact factor: 4.379

5.  Effect of Implant Angulation on the Rotational Displacement of a 3-Unit Bridge after Digital Impression.

Authors:  Mahnaz Arshad; Amirmohsen Asgari; Mohamad Javad Kharazifard; Narges Ameri
Journal:  Int J Dent       Date:  2022-01-25

Review 6.  Trueness and precision of digital implant impressions by intraoral scanners: a literature review.

Authors:  Minoru Sanda; Keita Miyoshi; Kazuyoshi Baba
Journal:  Int J Implant Dent       Date:  2021-07-27

Review 7.  Assessment of intraoral scanning technology for multiple implant impressions - A systematic review and meta-analysis.

Authors:  Saloni Kachhara; Deepak Nallaswamy; Dhanraj M Ganapathy; Vinay Sivaswamy; Vaishnavi Rajaraman
Journal:  J Indian Prosthodont Soc       Date:  2020-04-07

8.  Accuracy of digital and conventional dental implant impressions for fixed partial dentures: A comparative clinical study.

Authors:  Agne Gedrimiene; Rimas Adaskevicius; Vygandas Rutkunas
Journal:  J Adv Prosthodont       Date:  2019-10-30       Impact factor: 1.904