Literature DB >> 30302301

A Dorsal Approach for Ulnar Shortening Osteotomy.

Bo J W Notermans1, Wiesje Maarse1, Arnold H Schuurman1.   

Abstract

Aim  This study aims to evaluate the long-term complications, results, and patient satisfaction rates of a dorsally approached ulnar shortening osteotomy for ulnar impaction syndrome. Methods  A retrospective chart review of 20 patients was performed. Primary outcomes of interest were subjective, measured using the Patient-Rated Wrist Evaluation (PRWE) score, Disability of the Arm, Shoulder, and Hand (DASH) score, and the third questionnaire about patient satisfaction, composed by the authors. Secondary outcomes included hardware removal due to irritation and other complications. Results  Mean postoperative functional score of PRWE was 28 (standard deviation [SD], 30) and DASH 20 (SD, 26), respectively. Fifteen patients were satisfied with the operation. Removal of hardware was noted in six patients. In one patient plate breakage occurred. Conclusion  Similar postoperative functional scores and complications were seen in patients undergoing an ulnar shortening osteotomy with a dorsally placed plate for ulnar impaction syndrome, compared with other plate placement localizations. The incidence of plate removal is also comparable to previously described results. As the dorsally placed plate and freehand technique, are relatively easy, we feel that it has a place in the treatment of ulnar impaction syndrome. Level of Evidence  Level IV, retrospective cohort study.

Entities:  

Keywords:  dorsal approach; hardware removal; ulnar impaction syndrome; ulnar shortening osteotomy

Year:  2017        PMID: 30302301      PMCID: PMC6172606          DOI: 10.1055/s-0037-1608636

Source DB:  PubMed          Journal:  J Wrist Surg        ISSN: 2163-3916


  35 in total

1.  Freehand technique with the predrilled hole method for ulnar-shortening osteotomy.

Authors:  Hui-Kuang Huang; Jung-Pan Wang; Shih-Tien Wang; Yi-Chao Huang; Chien-Lin Liu
Journal:  J Chin Med Assoc       Date:  2015-09-07       Impact factor: 2.743

2.  Ulnar shortening osteotomy with a premounted sliding-hole plate.

Authors:  Hugo B Kitzinger; Birgit Karle; Steffen Löw; Hermann Krimmer
Journal:  Ann Plast Surg       Date:  2007-06       Impact factor: 1.539

3.  Comparison of ulnar-shortening osteotomy with a new Trimed dynamic compression system versus the Synthes dynamic compression system: clinical study.

Authors:  Shai Luria; Anthony J Lauder; Thomas E Trumble
Journal:  J Hand Surg Am       Date:  2008-11       Impact factor: 2.230

4.  Ulnar shortening with the ulna osteotomy locking plate.

Authors:  G Schmidle; R Arora; M Gabl
Journal:  Oper Orthop Traumatol       Date:  2012-07       Impact factor: 1.154

5.  Premature closure of the distal radial physis after fracture of the distal radial metaphysis.

Authors:  A Aminian; P L Schoenecker
Journal:  J Pediatr Orthop       Date:  1995 Jul-Aug       Impact factor: 2.324

6.  Outcomes of ulnar shortening osteotomy fixed with a dynamic compression system.

Authors:  Zahab S Ahsan; Yohan Song; Jeffrey Yao
Journal:  J Hand Surg Am       Date:  2013-07-03       Impact factor: 2.230

7.  Ulnar shortening osteotomy for ulnar ideopathic impaction syndrome.

Authors:  Annelies Moermans; Ilse Degreef; Luc De Smet
Journal:  Scand J Plast Reconstr Surg Hand Surg       Date:  2007

8.  Isolated ulnar shortening osteotomy for the treatment of extra-articular distal radius malunion.

Authors:  Ramesh C Srinivasan; Deeptee Jain; Marc J Richard; Fraser J Leversedge; Suhail K Mithani; David S Ruch
Journal:  J Hand Surg Am       Date:  2013-06       Impact factor: 2.230

Review 9.  Operative treatment of ulnar impaction syndrome: a systematic review.

Authors:  D J Stockton; M-E Pelletier; J M Pike
Journal:  J Hand Surg Eur Vol       Date:  2014-07-30

10.  Factors affecting results of ulnar shortening for ulnar impaction syndrome.

Authors:  Norimasa Iwasaki; Jyunichi Ishikawa; Hiroyuki Kato; Michio Minami; Akio Minami
Journal:  Clin Orthop Relat Res       Date:  2007-12       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.