Literature DB >> 30298453

Comparison of an indirect impression scanning system and two direct intraoral scanning systems in vivo.

Patricia Bosniac1, Peter Rehmann1, Bernd Wöstmann2.   

Abstract

OBJECTIVES: This in vivo study aimed to compare the marginal discrepancies of zirconia copings manufactured on the basis of two direct intraoral scanning systems and the indirect digitization of a conventional impression.
MATERIALS AND METHODS: A total of 63 teeth in 23 patients were prepared to receive full-coverage crowns. Subsequently, these teeth were intraorally scanned using CEREC AC Omnicam and Cara TRIOS and a conventional impression was taken with the scannable PVS Flexitime Fast & Scan. The conventional impression was then extraorally digitized using a D700 laboratory scanner. The zirconia copings were manufactured on the basis of the resulting datasets. Silicone replicas of the copings were produced and sectioned for the measurement of the marginal discrepancy under a digital microscope.
RESULTS: The statistical analysis showed no significant differences between the two intraoral scanners, the CEREC AC Omnicam (86.09 μm ± 61.46 μm) and the Cara TRIOS (88.95 μm ± 54.46 μm). However, the discrepancies of the zirconia copings obtained from the laboratory scans of conventional impressions (143.29 μm ± 100.71 μm) showed significant differences. Both intraoral scanners achieved a marginal discrepancy below 100 μm, whereas the laboratory scan exhibited considerably higher values.
CONCLUSIONS: The intraoral scanners tested allow for the production of single-tooth-restorations with an adequate marginal fit, whereas the production of restorations on the basis of the scan of a conventional impression led to vast marginal gaps. CLINICAL RELEVANCE: The method of digitizing a conventional impression using a laboratory scanner seemed to have reached its limits in the clinical environment.

Entities:  

Keywords:  Digital impression; Impression scan; Intraoral scanner; Marginal discrepancy

Year:  2018        PMID: 30298453     DOI: 10.1007/s00784-018-2679-4

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  7 in total

1.  Intraoral scanning to fabricate complete dentures with functional borders: a proof-of-concept case report.

Authors:  Alexey Unkovskiy; Eugen Wahl; Anne Teresa Zander; Fabian Huettig; Sebastian Spintzyk
Journal:  BMC Oral Health       Date:  2019-03-13       Impact factor: 2.757

2.  In-vitro evaluation of marginal and internal fit of 3-unit monolithic zirconia restorations fabricated using digital scanning technologies.

Authors:  Çise Özal; Mutahhar Ulusoy
Journal:  J Adv Prosthodont       Date:  2021-12-22       Impact factor: 1.904

3.  Comparison of marginal and internal fit of 5-unit zirconia fixed dental prostheses fabricated with CAD/CAM technology using direct and indirect digital scans.

Authors:  Irem Gokce Uluc; Mustafa Baris Guncu; Guliz Aktas; Ilser Turkyilmaz
Journal:  J Dent Sci       Date:  2021-07-30       Impact factor: 2.080

4.  In vitro comparative analysis of scanning accuracy of intraoral and laboratory scanners in measuring the distance between multiple implants.

Authors:  Reiji Natsubori; Shota Fukazawa; Toyokazu Chiba; Norimasa Tanabe; Hidemichi Kihara; Hisatomo Kondo
Journal:  Int J Implant Dent       Date:  2022-04-13

5.  In Vitro Comparison of Marginal and Internal Fit of Zirconia Copings Fabricated by One CAD/CAM System with Two Different Scanners.

Authors:  Zahra Khamverdi; Elmira Najafrad; Maryam Farhadian
Journal:  Front Dent       Date:  2021-01-20

6.  New Intraoral Scanner-Based Chairside Measurement Method to Investigate the Internal Fit of Crowns: A Clinical Trial.

Authors:  Maximiliane Amelie Schlenz; Jonas Vogler; Alexander Schmidt; Peter Rehmann; Bernd Wöstmann
Journal:  Int J Environ Res Public Health       Date:  2020-03-25       Impact factor: 3.390

7.  In vivo wear of CAD-CAM composite versus lithium disilicate full coverage first-molar restorations: a pilot study over 2 years.

Authors:  Jan-Frederik Güth; Kurt Erdelt; Christine Keul; Gintare Burian; Josef Schweiger; Daniel Edelhoff
Journal:  Clin Oral Investig       Date:  2020-05-12       Impact factor: 3.573

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.