Literature DB >> 30297540

Vertebral body stent augmentation to reconstruct the anterior column in neoplastic extreme osteolysis.

Alessandro Cianfoni1,2, Daniela Distefano1, Emanuele Pravatà1, Vittoria Espeli3, Gianfranco Pesce3, Pasquale Mordasini2, Luigi La Barbera4, Pietro Scarone5, Giuseppe Bonaldi6.   

Abstract

BACKGROUND: Extensive lytic lesions of the vertebral body (VB) increase risk of fracture and instability and require stabilization of the anterior column. Vertebral augmentation is an accepted treatment option, but when osteolysis has extensively destroyed the VB cortical boundaries (a condition herein defined as 'extreme osteolysis'), the risk of cement leakage and/or insufficient filling is high. Vertebral body stents (VBSs) might allow partial restoration of VB height, cement containment, and reinforcement, but their use in extreme osteolysis has not been investigated.
OBJECTIVE: To assess retrospectively the feasibility and safety of VBS augmentation in patients with 'extreme osteolysis' of the VB.
METHODS: We retrospectively analyzed 41 treated vertebrae (from T1 to L5). VB reconstruction was assessed on postprocedure CT images and rated on a qualitative 4-point scale (poor-fair-good-excellent). Clinical and radiological follow-up was performed at 1 month and thereafter at intervals in accordance with oncological protocols.
RESULTS: VBS augmentation was performed at 12 lumbar and 29 thoracic levels, with bilateral VBS in 23/41. VB reconstruction was judged satisfactory (good or excellent) in 37/41 (90%) of levels. Bilateral VBS received higher scores than unilateral (p=0.057, Pearson's X2). We observed no periprocedural complications. Cement leaks (epidural or foraminal) occurred at 5/41 levels (12.2%) without clinical consequences. Follow-up data were available for 27/29 patients, extending beyond 6 months for 20 patients (7-28 months, mean 15.3 months). VBS implant stability was observed in 40/41 cases (97.5%).
CONCLUSIONS: Our results support the use of VBS as a minimally invasive, safe and effective option for reconstructing the anterior column in prominent VB osteolysis. © Author(s) (or their employer(s)) 2019. No commercial re-use. See rights and permissions. Published by BMJ.

Entities:  

Keywords:  metastatic; neoplasm; spine; stent

Mesh:

Substances:

Year:  2018        PMID: 30297540     DOI: 10.1136/neurintsurg-2018-014231

Source DB:  PubMed          Journal:  J Neurointerv Surg        ISSN: 1759-8478            Impact factor:   5.836


  7 in total

1.  Armed Kyphoplasty: An Indirect Central Canal Decompression Technique in Burst Fractures.

Authors:  A Venier; L Roccatagliata; M Isalberti; P Scarone; D E Kuhlen; M Reinert; G Bonaldi; J A Hirsch; A Cianfoni
Journal:  AJNR Am J Neuroradiol       Date:  2019-10-24       Impact factor: 3.825

2.  Vertebral body cemented stents combined with posterior stabilization in the surgical treatment of metastatic spinal cord compression of the thoracolumbar spine.

Authors:  Riaz Mohammed; Maggie Lee; Shrijit Panikkar; Naveed Yasin; Kamran Hassan; Saeed Mohammad
Journal:  Surg Neurol Int       Date:  2020-07-25

3.  Vessel-Plasty Using Bone-Filling Mesh Container for Treatment of Malignant Severe Compression Fractures in Cervical Vertebrae.

Authors:  Yue Yang; Qinghua Tian; Tao Wang; Yingying Lu; Wenbin Li; Chungen Wu
Journal:  J Pain Res       Date:  2022-04-21       Impact factor: 2.832

4.  Stent-Screw Assisted Internal Fixation of Osteoporotic Vertebrae: A Comparative Finite Element Analysis on SAIF Technique.

Authors:  Luigi La Barbera; Alessandro Cianfoni; Andrea Ferrari; Daniela Distefano; Giuseppe Bonaldi; Tomaso Villa
Journal:  Front Bioeng Biotechnol       Date:  2019-10-25

5.  Mechanical Cavity Creation with Curettage and Vacuum Suction (Q-VAC) in Lytic Vertebral Body Lesions with Posterior Wall Dehiscence and Epidural Mass before Cement Augmentation.

Authors:  Eike I Piechowiak; Maurizio Isalberti; Marco Pileggi; Daniela Distefano; Joshua A Hirsch; Alessandro Cianfoni
Journal:  Medicina (Kaunas)       Date:  2019-09-24       Impact factor: 2.430

6.  Biomechanical comparison between unilateral and bilateral percutaneous vertebroplasty for osteoporotic vertebral compression fractures: A finite element analysis.

Authors:  Haowen Dai; Yang Liu; Qing Han; Aobo Zhang; Hao Chen; Yang Qu; Jincheng Wang; Jianwu Zhao
Journal:  Front Bioeng Biotechnol       Date:  2022-09-08

7.  Injectable Affinity and Remote Magnetothermal Effects of Bi-Based Alloy for Long-Term Bone Defect Repair and Analgesia.

Authors:  Yuanyuan He; Yu Zhao; Linlin Fan; Xuelin Wang; Minghui Duan; Hongzhang Wang; Xiyu Zhu; Jing Liu
Journal:  Adv Sci (Weinh)       Date:  2021-05-20       Impact factor: 16.806

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.