Demonstration of circumferential heterogeneity in displacement and strain in the abdominal aortic wall by spiral cine DENSE MRI.

Elizabeth Iffrig1, John S Wilson1,2, Xiadong Zhong2, John N Oshinski1,2.   

Abstract

BACKGROUND: Knowledge of tissue properties of the abdominal aorta can improve understanding of vascular disease and guide interventional approaches. Existing MRI methods to quantify aortic wall displacement and strain are unable to discern circumferential heterogeneity.
PURPOSE: To assess regional variation in abdominal aortic wall displacement and strain as a function of circumferential position using spiral cine displacement encoding with stimulated echoes (DENSE). STUDY TYPE: Prospective. POPULATION: Cardiovascular disease-free men (n = 8) and women (n = 9) ages 30-42. SEQUENCES: Prospective electrocardiogram (ECG)-gated and navigator echo-gated spiral, cine 2D DENSE and retrospective ECG-gated phase contrast MR (PCMR) sequences at 3T. ASSESSMENT: In-plane displacement values of the aortic wall acquired with DENSE were used to determine radial and circumferential aortic wall motion. A quadrilateral-based 2D strain calculation method was implemented to determine strain from the displacement field. Peak displacement and its radial and circumferential contributions as well as peak circumferential strain were compared among eight circumferential wall segments. Distensibility was calculated using PCMR and compared with homogenized circumferential strain. STATISTICAL TESTS: To account for repeated measurements in volunteers, linear mixed models for mean sector values were created for displacement magnitude, circumferential displacement, radial displacement, and circumferential strain. Comparisons were made between sectors. Calculated distensibility and homogenized circumferential strain were compared using Bland-Altman analysis. Statistical significance was defined as P < 0.05.
RESULTS: Displacement was highest in the anterior wall (1.5 ± 0.7 mm) and was primarily in the radial as compared with circumferential direction (1.04 ± 0.05 mm vs. 0.81 ± 0.42 mm). Circumferential strain was highest in the lateral walls (left 0.16 ± 0.05 and right 0.21 ± 0.12) with homogenized circumferential strain of 0.14 ± 0.05. DATA
CONCLUSION: DENSE imaging in the abdominal aortic wall demonstrated that the anterior aortic wall exhibits the greatest displacement, while the lateral wall experiences the largest circumferential strain. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;49:731-743.
© 2018 International Society for Magnetic Resonance in Medicine.

Entities:  

Year:  2018        PMID: 30295345     DOI: 10.1002/jmri.26304

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  3 in total

1.  A New Method for Quantifying Abdominal Aortic Wall Shear Stress Using Phase Contrast Magnetic Resonance Imaging and the Womersley Solution.

Authors:  Elizabeth Iffrig; Lucas H Timmins; Retta El Sayed; W Robert Taylor; John N Oshinski
Journal:  J Biomech Eng       Date:  2022-09-01       Impact factor: 1.899

2.  Accuracy of cardiac-induced brain motion measurement using displacement-encoding with stimulated echoes (DENSE) magnetic resonance imaging (MRI): A phantom study.

Authors:  Blaise Simplice Talla Nwotchouang; Maggie S Eppelheimer; Dipankar Biswas; Soroush Heidari Pahlavian; Xiaodong Zhong; John N Oshinski; Daniel L Barrow; Rouzbeh Amini; Francis Loth
Journal:  Magn Reson Med       Date:  2020-08-31       Impact factor: 4.668

3.  Regional Brain Tissue Displacement and Strain is Elevated in Subjects with Chiari Malformation Type I Compared to Healthy Controls: A Study Using DENSE MRI.

Authors:  Blaise Simplice Talla Nwotchouang; Maggie S Eppelheimer; Soroush Heidari Pahlavian; Jack W Barrow; Daniel L Barrow; Deqiang Qiu; Philip A Allen; John N Oshinski; Rouzbeh Amini; Francis Loth
Journal:  Ann Biomed Eng       Date:  2021-01-04       Impact factor: 4.219