Literature DB >> 30294786

International validation of harmonized definitions for complications of blood donations.

Kevin J Land1,2, Mary Townsend1, Mindy Goldman3, Barbee I Whitaker4, Gabriela E Perez4, Jo C Wiersum-Osselton5.   

Abstract

BACKGROUND: In December 2014, a multinational collaboration of hemovigilance experts from the International Society of Blood Transfusion (ISBT), the International Hemovigilance Network, and AABB published harmonized definitions of complications related to blood donation titled "Standard for Surveillance of Complications Related to Blood Donation." Both mandatory and optional terms were included. The definitions are endorsed by the Alliance of Blood Operators and the European Blood Alliance. STUDY DESIGN AND METHODS: The objective of this study was to validate harmonized donor hemovigilance definitions with potential users. In June 2016, 30 real-world cases were sent to potential users around the world along with the definitions, an answer sheet, and instructions on how to complete the validation exercise.
RESULTS: Overall, 54 responses from 25 countries were received, including over 400 comments. The results were presented for feedback at both ISBT and AABB meetings. Case diagnoses were consistent across most responders. Exceptions were rare adverse events, nonstandard presentations, or incomplete information. In general, the application of optional definitions, including severity grading and imputability, had the most variability.
CONCLUSION: The use of standardized terms in the donor setting serves to increase focus on donor safety, facilitate conversation, foster exchange of information, and frame questions for future research. Overall, the definitions provide adequate coverage of donor reactions; however, some terms require clarification. Severity grading and imputability and other optional terms need clear and objective definitions and instructions on when and how to use them. Additional feedback and final recommendations are summarized in this report.
© 2018 AABB.

Entities:  

Mesh:

Year:  2018        PMID: 30294786     DOI: 10.1111/trf.14948

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  3 in total

1.  Blood Donation-Related Adverse Reactions: Results of an Online Survey among Donors in Germany (2018).

Authors:  Stefano Orru'; Kay Poetzsch; Marcus Hoffelner; Margarethe Heiden; Markus B Funk; Brigitte Keller-Stanislawski; Doris Oberle
Journal:  Transfus Med Hemother       Date:  2021-03-31       Impact factor: 3.747

2.  Vasovagal reactions in whole blood and apheresis donors: a cross-sectional study on donor haemovigilance data from 2016 to 2019 in Italy.

Authors:  Vanessa Piccinini; Giuseppe Marano; Liviana Catalano; Ilaria Pati; Eva Veropalumbo; Chiara de Waure; Simonetta Pupella; Vincenzo De Angelis
Journal:  Blood Transfus       Date:  2021-09-22       Impact factor: 5.752

3.  Donor tolerability of convalescent plasma donation.

Authors:  Rui He; Hui Lin; Songli Xie; Qilu Lv; Yujie Kong; Ling Li; Haixia Xu; Jue Wang; Wenjuan Li; Peng Fang; Yanyun Wu; Zhong Liu
Journal:  J Clin Apher       Date:  2021-02-15       Impact factor: 2.605

  3 in total