Literature DB >> 30293824

Effects of freeze-thaw on the biomechanical and structural properties of the rat Achilles tendon.

N P Quirk1, C Lopez De Padilla1, R E De La Vega1, M J Coenen1, A Tovar1, C H Evans1, S A Müller2.   

Abstract

Rodent models are commonly used to investigate tendon healing, with the biomechanical and structural properties of the healed tendons being important outcome measures. Tendon storage for later testing becomes necessary when performing large experiments with multiple time-points. However, it is unclear whether freezing rodent tendons affects their material properties. Thus the aim of this study was to determine whether freezing rat Achilles tendons affects their biomechanical or structural properties. Tendons were frozen at either -20 °C or -80 °C directly after harvesting, or tested when freshly harvested. Groups of tendons were subjected to several freeze-thaw cycles (1, 2, and 5) within 3 months, or frozen for 9 months, after which the tendons were subjected to biomechanical testing. Additionally, fresh and thawed tendons were compared morphologically, histologically and by transmission electron microscopy. No major differences in biomechanical properties were found between fresh tendons and those frozen once or twice at -20 °C or -80 °C. However, deterioration of tendon properties was found for 5-cycle groups and both long-term freezing groups; after 9 months of freezing at -80 °C the tear resistance of the tendon was reduced from 125.4 ± 16.4N to 74.3 ± 18.4N (p = 0.0132). Moreover, tendons stored under these conditions showed major disruption of collagen fibrils when examined by transmission electron microscopy. When examined histologically, fresh samples exhibited the best cellularity and proteoglycan content of the enthesis. These properties were preserved better after freezing at -80 °C than after freezing at -20 °C, which resulted in markedly smaller chondrocytes and less proteoglycan content. Overall, the best preservation of histological integrity was seen with tendons frozen once at -80 °C. In conclusion, rat Achilles tendons can be frozen once or twice for short periods of time (up to 3 months) at -20 °C or -80 °C for later testing. However, freezing for 9 months at either -20 °C or -80 °C leads to deterioration of certain parameters.
Copyright © 2018 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Biomechanical testing; Freeze-thaw; Histology; Rat Achilles tendon; Ultra-structure

Mesh:

Year:  2018        PMID: 30293824     DOI: 10.1016/j.jbiomech.2018.09.012

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  6 in total

1.  Enthesis Healing Is Dependent on Scaffold Interphase Morphology-Results from a Rodent Patellar Model.

Authors:  Carlos J Peniche Silva; Sebastian A Müller; Nicholas Quirk; Patrina S P Poh; Carla Mayer; Antonella Motta; Claudio Migliaresi; Michael J Coenen; Christopher H Evans; Elizabeth R Balmayor; Martijn van Griensven
Journal:  Cells       Date:  2022-05-26       Impact factor: 7.666

2.  Structure and mechanical properties of high-weight-bearing and low-weight-bearing areas of hip cartilage at the micro- and nano-levels.

Authors:  Jiang-Bo Guo; Ting Liang; Yan-Jun Che; Hui-Lin Yang; Zong-Ping Luo
Journal:  BMC Musculoskelet Disord       Date:  2020-07-02       Impact factor: 2.362

3.  Cryopreservation of tendon tissue using dimethyl sulfoxide combines conserved cell vitality with maintained biomechanical features.

Authors:  Eva Hochstrat; Marcus Müller; Andre Frank; Philipp Michel; Uwe Hansen; Michael J Raschke; Daniel Kronenberg; Richard Stange
Journal:  PLoS One       Date:  2019-04-19       Impact factor: 3.240

4.  The influence of different sample preparation on mechanical properties of human iliotibial tract.

Authors:  Benjamin Fischer; Sascha Kurz; Andreas Höch; Stefan Schleifenbaum
Journal:  Sci Rep       Date:  2020-09-09       Impact factor: 4.379

5.  Effect of storage and preconditioning of healing rat Achilles tendon on structural and mechanical properties.

Authors:  Franciele Dietrich-Zagonel; Malin Hammerman; Magnus Bernhardsson; Pernilla Eliasson
Journal:  Sci Rep       Date:  2021-01-13       Impact factor: 4.379

6.  Assessment of Ligament Viscoelastic Properties Using Raman Spectroscopy.

Authors:  Andy Cui; Ervin Nippolainen; Rubina Shaikh; Jari Torniainen; Aapo Ristaniemi; Mikko Finnilä; Rami K Korhonen; Simo Saarakkala; Walter Herzog; Juha Töyräs; Isaac O Afara
Journal:  Ann Biomed Eng       Date:  2022-07-08       Impact factor: 4.219

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.