Literature DB >> 30293067

Effect of Increased Convection Volume by Mid-Dilution Hemodiafiltration on the Subclinical Chronic Inflammation in Maintenance Hemodialysis Patients.

Silvio Borrelli1, Roberto Minutolo2, Emanuele De Simone3, Walter De Simone3, MIchele Provenzano2, Luca De Nicola2, Giuseppe Conte2, Carlo Garofalo2.   

Abstract

Mid-dilution hemodiafiltration (MID) is a dialytic technique that might improve systemic inflammation of patients in chronic hemodialysis (HD) by increasing substitution volumes. To verify this hypothesis, we performed a prospective cross-over study comparing the effect on inflammatory biomarkers of higher convection by MID versus standard convection by post-dilution hemodiafiltration (HDF). Patients under chronic HD were therefore treated by MID and HDF by crossover design. Each treatment period lasted 4 months, with 1 month of wash-out where patients were treated by HD, for a total of 9 months. Primary outcome was the change of serum pre-dialytic C-Reactive Protein (CRP), interleukin 6 (IL-6), IL-1, IL-10, transforming growth factor-β (TGF-β), tumor necrosis factor-α, albumin and pre-albumin. Samples were obtained monthly. Ten HD patients were enrolled (age: 64.9 ± 12.6 years; 70% males; dialytic vintage: 10.6 [2.7-16.2] years). Mean convection volume was 40.1 ± 2.5 L/session in MID and 20.1 ± 2.6 L/session in HDF. A significant reduction of β2-Microglobulin was detected as a result of either treatment. In MID, CRP decreased from 11.3 (3.2-31.0) to 3.1 (1.4-14.4) mg/L (p = 0.007), IL-6 from 12.7 (5.0-29.7) to 8.3 (4.4-14.0) pg/mL (p = 0.003), and TGF-β from 10.6 (7.4-15.6) to 7.4 (5.9-9.3) ng/mL (p = 0.001). A significant reduction of CRP from 8.5 (3.2-31.0) to 4.6 (3.2-31.0) mg/L was also detected in HDF (p = 0.037), whereas no significant reduction of IL-6 (p = 0.147) and TGF-β (p = 0.094) was found. Percentage reduction of IL-6 correlated with mean convective volume in HDF (R = 0.666; p = 0.036) and in MID (R = 0.760; p = 0.020). Therefore, MID and HDF are associated with an attenuation of inflammatory pattern that is correlated with a high convective volume.
© 2018 S. Karger AG, Basel.

Entities:  

Keywords:  Hemodiafiltration; Inflammation; Mid-dilution

Mesh:

Substances:

Year:  2018        PMID: 30293067     DOI: 10.1159/000492377

Source DB:  PubMed          Journal:  Blood Purif        ISSN: 0253-5068            Impact factor:   2.614


  1 in total

Review 1.  The production of on-line dialysis water for extracorporeal dialysis: proposals for an increased safety upgrade: a viewpoint.

Authors:  Piergiorgio Bolasco
Journal:  J Nephrol       Date:  2019-11-12       Impact factor: 3.902

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.