Transesophageal echocardiography (TEE) has been extensively used historically for Transcatheter aortic valve implantation (TAVI) but focus is shifting from routine use of TEE and general anesthesia to "as needed" use. We evaluated patients who had TAVI in our institution from September 2012 to February 2017. Decision for implantation and use of TEE during procedure was made by the structural heart team on a case-to-case basis, based on FDA approved indications. Data including procedural details, length of stay and rehospitalizations were obtained from all patients. TAVI was performed on 178 patients during the study period of which 104 of 178 had TEE during TAVI. Baseline characteristics were fairly comparable in both groups. Similar proportion of self-expanding and balloon expanding valves were deployed. Patients in TEE group had longer overall procedure time (107 minute vs 83 minute, p = 0.0002) and longer length of stay (5.01days vs 2.49days, p < 0.0001). Echocardiographic study postprocedure showed similar incidence of paravalvular leak and similar gradients and velocities across aortic valve. Rates of 30-day readmissions were similar in both groups. In conclusion, in this single-center retrospective analysis-TAVI without the 'routine use' of TEE was comparable with those done with TEE guidance in terms of periprocedural complications and 30-day readmissions. Overall procedure length and length of stay was predictably higher in the TEE group.
Copyright © 2018. Published by Elsevier Inc.

Entities:  

Mesh:

Year:  2018        PMID: 30292281     DOI: 10.1016/j.amjcard.2018.06.037

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  3 in total

Review 1.  The Role of Multimodality Imaging in Transcatheter Aortic Valve Replacement.

Authors:  Qi Liu; Rebecca T Hahn
Journal:  Curr Cardiol Rep       Date:  2019-07-19       Impact factor: 2.931

2.  Transcatheter aortic valve replacement in patients with previous mitral valve replacement. A systematic study.

Authors:  Zbigniew Chmielak; Maciej Dąbrowski; Paweł Tyczyński; Krzysztof Kukuła; Ilona Michałowska; Emilia Szudejko; Jarosław Skowroński; Mariusz Kuśmierczyk; Adam Witkowski
Journal:  Postepy Kardiol Interwencyjnej       Date:  2020-06-23       Impact factor: 1.426

3.  Effect of procedural refinement of transfemoral transcatheter aortic valve implantation on outcomes and costs: a single-centre retrospective study.

Authors:  Sivasankar Sangaraju; Ian Cox; Malcolm Dalrymple-Hay; Clinton Lloyd; Venkatesan Suresh; Tania Riches; Samantha Melhuish; Sanjay Asopa; Samantha Newcombe; Cornelia Deutsch; Peter Bramlage
Journal:  Open Heart       Date:  2019-10-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.