Literature DB >> 30291206

Balloon remodeling-assisted Woven EndoBridge technique: description and feasibility for complex bifurcation aneurysms.

Cristian Mihalea1,2, Simon Escalard3, Jildaz Caroff1, Léon Ikka1, Aymeric Rouchaud4, Valerio Da Ros1,5, Igor Pagiola1,6, Joaquin Jose Marenco de la Torre1, Thomas Yasuda1, Bogdan Valeriu Popa7,8, Horia Ples2, Nidhal Benachour1, Augustin Ozanne1, Jacques Moret1, Laurent Spelle1.   

Abstract

BACKGROUND: Woven EndoBridge (WEB) deployment remains challenging in aneurysms with a complex shape or orientation.
OBJECTIVE: To show that embolization of wide-neck bifurcation aneurysms using the WEB device balloon remodeling-assisted technique is a feasible and elegant endovascular solution compared with other techniques, such as balloon remodeling or stent-assisted coiling.
MATERIALS AND METHODS: 10 cases (10 aneurysms in 9 patients) of balloon remodeling-assisted WEB treatment of unruptured complex bifurcation aneurysms were treated in our institution and retrospectively analyzed. Details of clinical presentations, technical details, perioperative and postoperative complications, and outcomes were collected. Immediate and long-term angiographic results were also evaluated.
RESULTS: Aneurysms included six middle cerebral artery aneurysms, one anterior communicating artery aneurysm, one posterior communicating artery aneurysm, one basilar artery aneurysm, and one T-shaped carotid aneurysm. Mean dome width was 6.55 mm, mean neck size 4.5 mm, mean height 4.79 mm, and mean dome-to-neck ratio was 1:1.46. Treatment was performed exclusively with the balloon remodeling-assisted WEB technique in all cases. The device was successfully deployed in every case. Periprocedural thromboembolic or hemorrhagic events did not occur. The modified Rankin Scale score at discharge was 0 for all patients. At mid-term or long-term angiographic follow-up, adequate occlusion was observed in 7 aneurysms from 8 controlled cases (87.5%), and one patient (2 aneurysms) did not have angiographic follow-up.
CONCLUSION: The balloon remodeling-assisted WEB technique seems to be a safe and effective solution for endovascular treatment of unruptured wide-neck bifurcation aneurysms with specific complex anatomy. However, further studies are needed to evaluate the rate of complications and long-term efficacy. © Author(s) (or their employer(s)) 2019. No commercial re-use. See rights and permissions. Published by BMJ.

Entities:  

Keywords:  aneurysm; balloon; intervention; stent; technique

Mesh:

Year:  2018        PMID: 30291206     DOI: 10.1136/neurintsurg-2018-014104

Source DB:  PubMed          Journal:  J Neurointerv Surg        ISSN: 1759-8478            Impact factor:   5.836


  4 in total

1.  The RISE trial: A Randomized Trial on Intra-Saccular Endobridge devices.

Authors:  Jean Raymond; Anne-Christine Januel; Daniela Iancu; Daniel Roy; Alain Weill; Andrew Carlson; Tim E Darsaut
Journal:  Interv Neuroradiol       Date:  2019-11-05       Impact factor: 1.610

2.  Intracranial aneurysm treatment with WEB and adjunctive stent: preliminary evaluation in a single-center series.

Authors:  Maher Sahnoun; Sébastien Soize; Pierre-François Manceau; Christophe Gelmini; Laurent Pierot
Journal:  J Neurointerv Surg       Date:  2021-03-30       Impact factor: 5.836

3.  CLinical Assessment of WEB device in Ruptured aneurYSms (CLARYS): results of 1-month and 1-year assessment of rebleeding protection and clinical safety in a multicenter study.

Authors:  Laurent Spelle; Denis Herbreteau; Jildaz Caroff; Xavier Barreau; Jean-Christophe Ferré; Jens Fiehler; Anne-Christine Januel; Vincent Costalat; Thomas Liebig; Romain Bourcier; Markus Möhlenbruch; Joachim Berkefeld; Werner Weber; Cristian Mihalea; Léon Ikka; Augustin Ozanne; Christophe Cognard; Ana Paula Narata; Richard Edwige Bibi; Jean-Yves Gauvrit; Hélène Raoult; Stéphane Velasco; Jan-Hendrik Buhk; Vanessa Chalumeau; Maxim Bester; Hubert Desal; Richard du Mesnil de Rochemont; Georg Bohner; Sebastian Fischer; Alessandra Biondi; Lamiae Grimaldi; Jacques Moret; James Byrne; Laurent Pierot
Journal:  J Neurointerv Surg       Date:  2021-09-07       Impact factor: 8.572