Literature DB >> 30288698

A robust method for segmenting pectoral muscle in mediolateral oblique (MLO) mammograms.

Kaiming Yin1, Shiju Yan2, Chengli Song1, Bin Zheng3.   

Abstract

PURPOSE: Accurately detecting and removing pectoral muscle areas depicting on mediolateral oblique (MLO) view mammograms are an important step to develop a computer-aided detection scheme to assess global mammographic density or tissue patterns. This study aims to develop and test a new fully automated, accurate and robust method for segmenting pectoral muscle in MLO mammograms.
METHODS: The new method includes the following steps. First, a small rectangular region in the top-left corner of the MLO mammogram which may contain pectoral muscle is captured and enhanced by the fractional differential method. Next, an improved iterative threshold method is applied to segment a rough binary boundary of the pectoral muscle in the small region. Then, a rough contour is fitted with the least squares method on the basis of points of the rough boundary. Last, the fitting contour is subjected to local active contour evolution to obtain the final pectoral muscle segmentation line. The method has been tested on 720 MLO mammograms.
RESULTS: The segmentation results generated using the new scheme were evaluated by two expert mammographic radiologists using a 5-scale rating system. More than 65% were rated above scale 3. When assessing the segmentation results generated using Hough transform, morphologic thresholding methods and Unet-based model, less than 20%, 35% and 47% of segmentation results were rated above scale 3 by two radiologists, respectively. Quantitative data analysis results show that the Dice coefficient of 0.986 ± 0.005 is obtained. In addition, the mean rate of errors and Hausdorff distance between the contours detected by automated and manual segmentation are FP = 1.71 ± 3.82%, FN = 5.20 ± 3.94% and 2.75 ± 1.39 mm separately.
CONCLUSION: The proposed method can be used to segment the pectoral muscle in MLO mammograms with higher accuracy and robustness.

Keywords:  Automated segmentation; Computer-aided diagnosis; Mediolateral oblique mammograms; Pectoral muscle

Mesh:

Year:  2018        PMID: 30288698     DOI: 10.1007/s11548-018-1867-7

Source DB:  PubMed          Journal:  Int J Comput Assist Radiol Surg        ISSN: 1861-6410            Impact factor:   2.924


  1 in total

1.  Development and Assessment of a New Global Mammographic Image Feature Analysis Scheme to Predict Likelihood of Malignant Cases.

Authors:  Morteza Heidari; Seyedehnafiseh Mirniaharikandehei; Wei Liu; Alan B Hollingsworth; Hong Liu; Bin Zheng
Journal:  IEEE Trans Med Imaging       Date:  2019-10-09       Impact factor: 10.048

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.