Literature DB >> 30286276

Microfluidic electrochemical immunosensor for the trace analysis of cocaine in water and body fluids.

Nahla A Abdelshafi1,2, Jérémy Bell1, Knut Rurack1, Rudolf J Schneider1,3.   

Abstract

Quick but accurate testing and on-the-spot monitoring of cocaine in oral fluids and urine continues to be an important toxicological issue. In terms of drug testing, a number of devices have been introduced into the market in recent decades, notably for workplace inspection or roadside testing. However, these systems do not always fulfill the requirements in terms of reliability, especially when low cut-off levels are required. With respect to surface water, the presence of anthropogenic small organic molecules such as prescription and over-the-counter pharmaceuticals as well as illicit drugs like cannabinoids, heroin, or cocaine, has become a challenge for scientists to develop new analytical tools for screening and on-site analysis because many of them serve as markers for anthropogenic input and consumer behavior. Here, a modular approach for the detection of cocaine is presented, integrating an electrochemical enzyme-linked immunosorbent assay (ELISA) performed on antibody-grafted magnetic beads in a hybrid microfluidic sensor utilizing flexible tubing, static chip and screen-printed electrode (SPE) elements for incubation, recognition, and cyclic voltammetry measurements. A linear response of the sensor vs. the logarithm of cocaine concentration was obtained with a limit of detection of 0.15 ng/L. Within an overall assay time of 25 minutes, concentrations down to 1 ng/L could be reliably determined in water, oral fluids, and urine, the system possessing a dynamic working range up to 1 mg/L.
© 2018 John Wiley & Sons, Ltd.

Entities:  

Keywords:  Cocaine; ELISA; Lab-on-chip; Saliva; Urine

Mesh:

Substances:

Year:  2018        PMID: 30286276     DOI: 10.1002/dta.2515

Source DB:  PubMed          Journal:  Drug Test Anal        ISSN: 1942-7603            Impact factor:   3.345


  4 in total

Review 1.  Interpol review of controlled substances 2016-2019.

Authors:  Nicole S Jones; Jeffrey H Comparin
Journal:  Forensic Sci Int Synerg       Date:  2020-05-24

Review 2.  Screen-Printed Electrodes (SPE) for In Vitro Diagnostic Purpose.

Authors:  Nicolae-Bogdan Mincu; Veronica Lazar; Dana Stan; Carmen Marinela Mihailescu; Rodica Iosub; Andreea Lorena Mateescu
Journal:  Diagnostics (Basel)       Date:  2020-07-26

3.  Microfluidic nanodevices for drug sensing and screening applications.

Authors:  Arnab Pal; Kuldeep Kaswan; Snigdha Roy Barman; Yu-Zih Lin; Jun-Hsuan Chung; Manish Kumar Sharma; Kuei-Lin Liu; Bo-Huan Chen; Chih-Cheng Wu; Sangmin Lee; Dongwhi Choi; Zong-Hong Lin
Journal:  Biosens Bioelectron       Date:  2022-10-05       Impact factor: 12.545

Review 4.  Aptasensors for Point-of-Care Detection of Small Molecules.

Authors:  Marc Prante; Ester Segal; Thomas Scheper; Janina Bahnemann; Johanna Walter
Journal:  Biosensors (Basel)       Date:  2020-08-26
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.