BACKGROUND: Some patients with congestive heart failure have greater improvement of cardiac remodelling after cardiac resynchronisation therapy (CRT) and they are identified as super-responders (SRs). It remains unclear if echocardiographic markers of dyssynchrony could accuratelly predict super-response to CRT. The aim of this study is to evaluate potential echocardiographic predictors associated with super-response to CRT.Entities:
Keywords: Cardiac resynchronisation therapy; Dyssynchrony; Super-response
Mesh:
Year: 2018 PMID: 30285762 PMCID: PMC6167795 DOI: 10.1186/s12947-018-0140-0
Source DB: PubMed Journal: Cardiovasc Ultrasound ISSN: 1476-7120 Impact factor: 2.062
Baseline characteristics of the study groups
| Parameter | I group ( | II group ( |
| |
|---|---|---|---|---|
| Age, (years) | 52.9 ± 9.0 | 52.0±7.6 | 53.4±9.7 | 0.624 |
| Men, (n) | 88% (52/59) | 85% (17/20) | 90% (35/39) | 0.594 |
| CAD, (%) | 54 | 47 | 60 | 0.308 |
| NYHA functional class | 2.8±0.6 | 2.6±0.6 | 2.8±0.6 | 0.110 |
| LBBB, (%) | 59 | 50 | 64 | 0.297 |
| QRS, (ms) | 140.9 ± 38.9 | 139.1±44.2 | 141.8±36.7 | 0.997 |
| Atrial fibrillation, (%) | 34 | 25 | 38 | 0.301 |
| LVEDV, (ml) | 231.9±65.1 | 233.4±65.0 | 231.2±65.9 | 0.288 |
| LVESV, (ml) | 163.5±49.4 | 163.4±46.5 | 163.5±51.3 | 0.475 |
| LVEF, (%) | 29.8±3.6 | 30.0±2.7 | 29.6±3.9 | 0.458 |
Tables. 1 and 2: M ± SD - mean ± standard deviation, CAD – coronary artery disease, NYHA – New York Heart Association, LBBB- left bundle branch block, LVESV – left ventricular end-systolic volume, LVEDV – left ventricular end-diastolic volume, LVEF – left ventricular ejection fraction
Clinical and functional characteristics at baseline and after 6 months of CRT
| Parameter | I group ( | II group ( |
| |
|---|---|---|---|---|
| NYHA functional class | At baseline | 2.6±0.6 | 2.8±0.6 | 0.107 |
| After 6 months | 1.9±0.7a | 2.2±0.9a | 0.169 | |
| 6-min walking distance, (m) | At baseline | 329.2±86.0 | 320.9±98.7 | 0.651 |
| After 6 months | 421.5±66.7a | 381.5±112.2a | 0.169 | |
| LVEF by 3D echocardiography, (%) | At baseline | 30.0±2.7 | 29.6±3.9 | 0.458 |
| After 6 months | 40.1±5.4a | 34.4±3.8a | < 0.001 | |
| Mean changes | 10[6.2;13.2] | 5[3;7] | < 0.001 | |
| LVEDV by 3D echocardiography, (ml) | At baseline | 233.4±65.0 | 231.2±65.9 | 0.820 |
| After 6 months | 159.1±39.4a | 213.2±63.7a | < 0.001 | |
| Mean changes | −73.0[− 101.0;-51.7] | −15.0[− 31.0;-8.0] | < 0.001 | |
| LVESV by 3D echocardiography, (ml) | At baseline | 163.4±46.5 | 163.5±51.3 | 0.957 |
| After 6 months | 95.8±27.1a | 140.0±46.7a | < 0.001 | |
| Mean changes | −61.0[−91.0;-47.7] | − 20.0[− 38.0;-12.0] | < 0.001 | |
| QRS, (ms) | At baseline | 139.1±44.2 | 141.8±36.7 | 0.996 |
| After 6 months | 153.6±26.2 | 160.2±26.0a | 0.367 | |
a – difference between baseline and postimplant value (р < 0.05)
Parameters of mechanical dyssynchrony at baseline and after 6 months of CRT
| Parameter | I group ( | II group ( |
| |
|---|---|---|---|---|
| Systolic dyssynchrony index, (%) | At baseline | 9.5±3.4 | 7.5±4.4 | 0.05 |
| After 6 months | 2.8±1.2a | 3.1±1.2a | 0.278 | |
| Mean changes | −6.4[−8.7;-4.3] | −2.8[− 8.2;-0.36] | 0.044 | |
| Left ventricular pre-ejection period, (ms) | At baseline | 160.5±31.2 | 131.5±29.5 | 0.002 |
| After 6 months | 127.7±22.8a | 118.3±21.2a | 0.292 | |
| Mean changes | −35.5[−53.7;-11.2] | −18.5[− 35.0;1.7] | 0.043 | |
| Right ventricular pre-ejection period, (ms) | At baseline | 102.1±21.4 | 95.4±18.6 | 0.249 |
| After 6 months | 106.4±16.7 | 103.3±26.2 | 0.716 | |
| Mean changes | 9.5[−17.0;30.7] | 14.5[−13.5;33.5] | 0.512 | |
| Interventricular mechanical delay, (ms) | At baseline | 57.5±28.3 | 39.7±24.2 | 0.024 |
| After 6 months | 19.9±15.9a | 25.4±11.7 | 0.357 | |
| Mean changes | −47.0[−55.0;-13.0] | −11.0[−36.5;3.0] | 0.054 | |
| Interventricular delay by TDI, (ms) | At baseline | 110.2±66.1 | 71.6±57.9 | 0.038 |
| After 6 months | 58.4±56.7a | 50.6±48.3a | 0.653 | |
| Mean changes | −31.0[−120;12.5] | −20.5[−66.2;8.2] | 0.165 | |
| Intraventricular delay by TDI, (ms) | At baseline | 88.4±45.3 | 67.7±42.8 | 0.098 |
| After 6 months | 54.7±44.9a | 36.9±25.5 | 0.568 | |
| Mean changes | −57.5[−80.2;-28.0] | −12.0[− 40.0;15.0] | 0.005 | |
TDI – tissue Doppler imaging
a – difference between baseline and postimplant level (р < 0.05)