Literature DB >> 30283998

Non-invasive monitoring of blood glucose using optical methods for skin spectroscopy-opportunities and recent advances.

Sven Delbeck1, Thorsten Vahlsing2,3, Steffen Leonhardt3, Gerald Steiner4, H Michael Heise5.   

Abstract

Diabetes mellitus is a widespread disease with greatly rising patient numbers expected in the future, not only for industrialized countries but also for regions in the developing world. There is a need for efficient therapy, which can be via self-monitoring of blood glucose levels to provide tight glycemic control for reducing the risks of severe health complications. Advancements in diabetes technology can nowadays offer different sensor approaches, even for continuous blood glucose monitoring. Non-invasive blood glucose assays have been promised for many years and various vibrational spectroscopy-based methods of the skin are candidates for achieving this goal. Due to the small spectral signatures of the glucose hidden among a largely variable background, the largest signal-to-noise ratios and multivariate calibration are essential to provide the method applicability for self-monitoring of blood glucose. Besides multiparameter approaches, recently presented devices based on photoplethysmography with wavelengths in the visible and near-infrared range are evaluated for their potential of providing reliable blood glucose concentration predictions. Graphical abstract ᅟ.

Entities:  

Keywords:  Color sensing; Multivariate calibration; Non-invasive glucose sensing; Photoplethysmography; Validation studies; Vibrational spectroscopy

Mesh:

Substances:

Year:  2018        PMID: 30283998     DOI: 10.1007/s00216-018-1395-x

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  11 in total

1.  Enhanced terahertz sensitivity for glucose detection with a hydrogel platform embedded with Au nanoparticles.

Authors:  Jingjing Zhao; Shaohua Lu; Julio Bastos-Arrieta; Cristina Palet; Yiling Sun; Renheng Wang; Zhengfang Qian; Shuting Fan
Journal:  Biomed Opt Express       Date:  2022-06-22       Impact factor: 3.562

Review 2.  [Treatment of diabetes mellitus in perioperative medicine-an update].

Authors:  B Rupprecht; A Stöckl; S Stöckl; C Dietrich
Journal:  Anaesthesist       Date:  2020-11-03       Impact factor: 1.041

3.  Proof of Concept for a New Raman-Based Prototype for Noninvasive Glucose Monitoring.

Authors:  Stefan Pleus; Sebastian Schauer; Nina Jendrike; Eva Zschornack; Manuela Link; Karl Dietrich Hepp; Cornelia Haug; Guido Freckmann
Journal:  J Diabetes Sci Technol       Date:  2020-08-12

4.  Evaluation of Opportunities and Limitations of Mid-Infrared Skin Spectroscopy for Noninvasive Blood Glucose Monitoring.

Authors:  Sven Delbeck; H Michael Heise
Journal:  J Diabetes Sci Technol       Date:  2020-06-26

5.  Noninvasive Monitoring of Glucose Using Near-Infrared Reflection Spectroscopy of Skin-Constraints and Effective Novel Strategy in Multivariate Calibration.

Authors:  H Michael Heise; Sven Delbeck; Ralf Marbach
Journal:  Biosensors (Basel)       Date:  2021-02-27

Review 6.  Products for Monitoring Glucose Levels in the Human Body With Noninvasive Optical, Noninvasive Fluid Sampling, or Minimally Invasive Technologies.

Authors:  Trisha Shang; Jennifer Y Zhang; Andreas Thomas; Mark A Arnold; Beatrice N Vetter; Lutz Heinemann; David C Klonoff
Journal:  J Diabetes Sci Technol       Date:  2021-06-13

7.  Diabetes Technology Meeting 2020.

Authors:  Trisha Shang; Jennifer Y Zhang; B Wayne Bequette; Jennifer K Raymond; Gerard Coté; Jennifer L Sherr; Jessica Castle; John Pickup; Yarmela Pavlovic; Juan Espinoza; Laurel H Messer; Tim Heise; Carlos E Mendez; Sarah Kim; Barry H Ginsberg; Umesh Masharani; Rodolfo J Galindo; David C Klonoff
Journal:  J Diabetes Sci Technol       Date:  2021-07

8.  Perspective on the increasing role of optical wearables and remote patient monitoring in the COVID-19 era and beyond.

Authors:  Darren Roblyer
Journal:  J Biomed Opt       Date:  2020-10       Impact factor: 3.170

Review 9.  Comprehensive Review on Wearable Sweat-Glucose Sensors for Continuous Glucose Monitoring.

Authors:  Hima Zafar; Asma Channa; Varun Jeoti; Goran M Stojanović
Journal:  Sensors (Basel)       Date:  2022-01-14       Impact factor: 3.576

10.  A Single Wavelength Mid-Infrared Photoacoustic Spectroscopy for Noninvasive Glucose Detection Using Machine Learning.

Authors:  Abdulrahman Aloraynan; Shazzad Rassel; Chao Xu; Dayan Ban
Journal:  Biosensors (Basel)       Date:  2022-03-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.