Literature DB >> 30282601

Accuracy of cadmium-zinc-telluride imaging in detecting single and multivessel coronary artery disease: Is there any gender difference?

Alessia Gimelli1, Nicola Riccardo Pugliese2, Annette Kusch1, Assuero Giorgetti1, Paolo Marzullo3.   

Abstract

PURPOSE: To evaluate gender-related differences in diagnostic accuracy of cadmium‑zinc-telluride (CZT) myocardial perfusion imaging in detecting single- and multi-vessel coronary artery disease (CAD).
METHODS: We prospectively enrolled 1161 consecutive patients with known or suspected coronary artery disease (288, 25% women and 873, 75% men) who had been referred to our laboratory for stress-rest myocardial perfusion imaging (single-day stress-rest protocol, mean radiation dose: 4 mSv). All patients underwent coronary angiography within 30 days; significant CAD was defined in the presence of a coronary stenosis >70%. Summed stress scores (SSS), summed rest scores (SRS) and summed difference scores (SDS) were obtained. Image quality was graded "good" or better in >90% of patients.
RESULTS: On coronary angiography, left main trunk, left anterior descending artery, left circumflex artery and right coronary artery obstructive stenosis were seen in 13, 486, 393 and 499 patients, respectively. Global SSS was the best predictor of CAD in women (AUC = 0.866, 81% sensitivity and 79% specificity) and in men (AUC = 0.871, 76% sensitivity and 84% specificity). Interestingly, its accuracy was maintained also in patients with two-vessel (women: AUC = 0.842, p < 0.001; men: AUC 0.839, p < 0.001) or three-vessel disease (women: AUC = 0.800, p < 0.001; men: AUC 0.804, p < 0.001). There was no gender-related difference in terms of diagnostic accuracy.
CONCLUSIONS: Evaluation of multivessel disease can be obtained by CZT camera in men as well as in women, with high accuracy at a lower radiation exposure.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cadmium‑zinc-telluride; Coronary artery disease; Multi-vessel disease; Myocardial perfusion imaging; Women

Mesh:

Substances:

Year:  2018        PMID: 30282601     DOI: 10.1016/j.ijcard.2018.09.102

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  1 in total

1.  Evaluation data about accuracy of cadmium-zinc-telluride imaging in detecting single and multivessel coronary artery disease: Focus on gender differences.

Authors:  Alessia Gimelli; Nicola Riccardo Pugliese; Annette Kusch; Assuero Giorgetti; Paolo Marzullo
Journal:  Data Brief       Date:  2018-11-01
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.