Literature DB >> 30281183

Clinical Comparative Evaluation of Nd:YAG Laser and a New Varnish Containing Casein Phosphopeptides-Amorphous Calcium Phosphate for the Treatment of Dentin Hypersensitivity: A Prospective Study.

Fady Bou Chebel1, Carina Mehanna Zogheib2, Nadim Z Baba2, Karim A Corbani1.   

Abstract

PURPOSE: The aim of this study was to compare the effect of Nd:YAG laser to that of a new varnish: MI Varnish with RECALDENT (GC), for the treatment of dentin hypersensitivity, with a follow-up of 6 months. Dentinal hypersensitivity was evaluated using a new thermal test never before used on dental tissue.
MATERIALS AND METHODS: A split-mouth design was used where teeth on one side received the same type of treatment. Twelve patients suffering from dentin hypersensitivity were chosen. Fifty-four teeth were divided into 27 pairs. Twenty-seven teeth received the Nd:YAG laser treatment, and the 27 contralateral teeth received MI Varnish application. Five parameters were measured, and the measurements were taken before treatment at baseline (T0), after 1 week (T1), 1 month (T2), 3 months (T3), and 6 months (T4) of the application. Air stimulation to obtain the Schiff air score, the score of discomfort according to the visual analog scale (VAS), the tactile score, and the thermal test that determines the minimum cold-stimulating temperature and the maximum heat-stimulating temperature were all used to assess sensitivity. Statistical analyses of the data were performed, and the significance level was set at p ≤ 0.05. Exact Fisher tests and Chi-Square tests were conducted to compare percentages.
RESULTS: There was a clear decrease in dentin hypersensitivity for both treatments (Nd:YAG laser and MI Varnish) especially between baseline and 1 week, with maintenance of this state through the 6-month follow-up period. The difference between the two treatments was not significant, comparing, over time, the Schiff air score, the thermal test, and the VAS; however, the tactile score was significantly improved 6 months after the application of MI Varnish compared to the laser (p = 0.05).
CONCLUSION: There was no significant difference between the two treatments, Nd:YAG laser and MI Varnish. Both treatments were effective and reduced dentin hypersensitivity immediately after treatment up to 6 months.
© 2018 by the American College of Prosthodontists.

Entities:  

Keywords:  Amorphous calcium; MI Varnish; Nd:YAG laser; casein phosphopeptide; dentin hypersensitivity

Mesh:

Substances:

Year:  2018        PMID: 30281183     DOI: 10.1111/jopr.12984

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  4 in total

1.  Comparative evaluation of the efficacy of the desensitizing and remineralizing agent in the reduction of dentin hypersensitivity after orthodontic debonding - a randomized clinical trial.

Authors:  Sasipriya Vatturu; Vivek Reddy Ganugapanta; Naga Ravi Teja; Gowri Sankar Singaraju; Prasad Mandava; Js Yamini Priyanka
Journal:  Med Pharm Rep       Date:  2021-04-29

Review 2.  Effects of low-level light therapy on dentin hypersensitivity: a systematic review and meta-analysis.

Authors:  Zhiyi Shan; Juanjuan Ji; Colman McGrath; Min Gu; Yanqi Yang
Journal:  Clin Oral Investig       Date:  2021-10-13       Impact factor: 3.573

3.  Laser therapy for dentinal hypersensitivity.

Authors:  Mina Mahdian; Soodabeh Behboodi; Yumi Ogata; Zuhair S Natto
Journal:  Cochrane Database Syst Rev       Date:  2021-07-13

4.  Effect of the casein phosphopeptide-amorphous calcium phosphate fluoride (CPP-ACPF) and photobiomodulation (PBM) on dental hypersensitivity: A randomized controlled clinical trial.

Authors:  Mariangela Ivette Guanipa Ortiz; Cristiane de Melo Alencar; Brennda Lucy Freitas De Paula; Eliane Bemerguy Alves; Jesuína Lamartine Nogueira Araújo; Cecy Martins Silva
Journal:  PLoS One       Date:  2019-12-02       Impact factor: 3.752