Literature DB >> 30280217

Computed tomography evaluation of total knee arthroplasty implants position after two different surgical methods of implantation.

Francesco Benazzo1, Stefano Marco Paolo Rossi1, Gianmarco Danesino2, Catherine Klersy3, Simone Perelli1, Matteo Ghiara4.   

Abstract

PURPOSE: The objectives of this study were to determine the reliability of a novel method of measuring the rotational alignment of an anatomical tibial tray, the difference in the rotational alignment of the femoral and tibial component according to pure measured resection or blended technique with tensor, and, finally, the difference in terms of clinical results according to the two different methods. PATIENTS AND METHODS: We performed a total of 60 consecutive TKAs: 30 according to pure measured resection and 30 according to blended technique with tensor (FuZion®). Clinical scores and CT scan were done at six months to measure patient's outcome and prosthetic components rotation.
RESULTS: The method of measurement of tibial tray had high agreement between different radiological observers. Mean external rotation alignment of the femur was 2.7° in standard group and 0.5° in the FuZion® group. For all clinical indices, we observed a large and significant improvement at follow-up, better in blended technique group, but without a clear superiority, and no statistically significant difference was evident between the two groups. At follow-up, HSS was to 89.7 in the FuZion® group and 89.0 in the standard group, KSS (clinical) was 92.6 in and 91.3 respectively, and KSS (Functional) was 91.0 in the FuZion® group and 87.6 in the standard group.
CONCLUSIONS: Our CT measurement method is reliable and reproducible. All patients operated with this personalized knee system design obtained excellent results; the customization of femoral rotation with a blended technique is, probably, the key to optimize the outcomes and achieve the state of forgotten knee.

Entities:  

Keywords:  Blended technique with tensor; CT measurement TKA rotation; Measured resection and gap balancing; Personalized TKA design

Mesh:

Year:  2018        PMID: 30280217     DOI: 10.1007/s00264-018-4180-8

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  18 in total

1.  Internal rotation of the tibial component is frequent in stiff total knee arthroplasty.

Authors:  Martin Bédard; Kelly G Vince; John Redfern; Stacy R Collen
Journal:  Clin Orthop Relat Res       Date:  2011-04-30       Impact factor: 4.176

Review 2.  Rotational alignment of the distal femur: a literature review.

Authors:  J Victor
Journal:  Orthop Traumatol Surg Res       Date:  2009-07-09       Impact factor: 2.256

Review 3.  Total knee arthroplasties from the origin to navigation: history, rationale, indications.

Authors:  Dominique Saragaglia; Brice Rubens-Duval; Julia Gaillot; Gabriel Lateur; Régis Pailhé
Journal:  Int Orthop       Date:  2018-03-27       Impact factor: 3.075

Review 4.  What are the factors of residual pain after uncomplicated TKA?

Authors:  Michel P Bonnin; Luca Basiglini; H A Pooler Archbold
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-05-20       Impact factor: 4.342

5.  Is computed tomography an accurate and reliable method for measuring total knee arthroplasty component rotation?

Authors:  José Figueroa; Juan Pablo Guarachi; José Matas; Magnus Arnander; Mario Orrego
Journal:  Int Orthop       Date:  2015-07-25       Impact factor: 3.075

6.  Femoral component rotation and arthrofibrosis following mobile-bearing total knee arthroplasty.

Authors:  J G Boldt; J B Stiehl; J Hodler; M Zanetti; U Munzinger
Journal:  Int Orthop       Date:  2006-03-07       Impact factor: 3.075

7.  The trivector approach for minimally invasive total knee arthroplasty: a technical note.

Authors:  Francesco Benazzo; Stefano Marco Paolo Rossi
Journal:  J Orthop Traumatol       Date:  2012-04-17

Review 8.  Gap balancing vs. measured resection technique in total knee arthroplasty.

Authors:  Brian K Daines; Douglas A Dennis
Journal:  Clin Orthop Surg       Date:  2014-02-14

9.  Effects of the balanced gap technique on femoral component rotation in TKA.

Authors:  Petra J C Heesterbeek; Wilco C H Jacobs; Ate B Wymenga
Journal:  Clin Orthop Relat Res       Date:  2008-10-02       Impact factor: 4.176

Review 10.  Comparison of soft tissue balancing, femoral component rotation, and joint line change between the gap balancing and measured resection techniques in primary total knee arthroplasty: A meta-analysis.

Authors:  Young-Wan Moon; Hyun-Jung Kim; Hyeong-Sik Ahn; Chan-Deok Park; Dae-Hee Lee
Journal:  Medicine (Baltimore)       Date:  2016-09       Impact factor: 1.889

View more
  5 in total

1.  The history of Italian Orthopaedics.

Authors:  Matteo Papalia; Francesco Falez
Journal:  Int Orthop       Date:  2019-01       Impact factor: 3.075

Review 2.  Methods of intra- and post-operative determination of the position of the tibial component during total knee replacement.

Authors:  Roman Popescu; Emil G Haritinian; Stefan Cristea
Journal:  Int Orthop       Date:  2019-10-27       Impact factor: 3.075

3.  Determining the rotational alignment of the tibial component referring to the tibial tubercle during total knee arthroplasty: the tibial tubercle-trochlear groove can be an aid.

Authors:  He Zhang; Chengming Cao; Han Zhang; Shoujiang Han
Journal:  J Orthop Surg Res       Date:  2022-05-04       Impact factor: 2.677

4.  Can the Surgical Approach to Total Knee Arthroplasty Influence Early Postoperative Outcomes? - A Comparative Study between Trivector and Medial Parapatellar Approaches.

Authors:  Gautam Reddy; Saif Ul Islam; Prakash Chandran; Fahad Attar
Journal:  Int J Appl Basic Med Res       Date:  2020-01-03

5.  In vivo kinematics of cruciate-retaining total knee arthroplasty after a change of polyethylene insert configuration.

Authors:  Shotaro Watanabe; Tetsuya Tomita; Ryuichiro Akagi; Atsuya Watanabe; Takaharu Yamazaki; Takahiro Enomoto; Ryosuke Nakagawa; Seiji Kimura; Seiji Ohtori; Takahisa Sasho
Journal:  Asia Pac J Sports Med Arthrosc Rehabil Technol       Date:  2020-12-31
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.