Literature DB >> 30279933

Trans-catheter aortic valve implantation without contrast using the Lotus mechanically-expanded heart valve.

Noman Ali1, Smriti Saraf1, Dominik Schlosshan1, Michael Cunnington1, Christopher J Malkin1, Daniel J Blackman1.   

Abstract

Trans-catheter aortic valve implantation (TAVI) has become an established treatment for inoperable and high-surgical risk patients with severe, symptomatic aortic stenosis (AS). Post-procedural acute kidney injury (AKI) is a frequent complication following TAVI and is associated with increased mortality. Patients with pre-existing chronic renal impairment are at particularly high risk. The etiology of post-TAVI AKI is multi-factorial, but the principal procedural issues are contrast-induced nephropathy, and renal hypoperfusion secondary to intra-procedural hypotension. We report a case of a TAVI in an 80-year-old patient with severe AS and significant chronic kidney disease (CKD), which was carried out without the use of contrast and with minimal procedural hypotension. Pre-procedural imaging was carried out using 3D trans-esophageal echocardiography (TEE) rather than computed tomography (CT) to avoid contrast administration. The Lotus valve (Boston Scientific, Marlborough, MA, USA) was chosen due to a number of design features which minimize both the need for contrast injection and procedural hypotension during valve positioning and deployment. The procedure was carried out successfully and produced an excellent result with no decline in renal function. We believe that the approach of using TEE and the mechanically-expanded Lotus valve illustrates an important therapeutic approach in patients with severe CKD. <Learning objective: Post-procedural acute kidney injury (AKI) is a frequent complication following trans-catheter aortic valve implantation (TAVI), and is associated with increased mortality. The principal procedural issues are contrast-induced nephropathy and intra-procedural hypotension. Our case report demonstrates how TAVI can be performed with zero contrast and minimization of procedural hypotension, facilitated by the use of trans-esophageal echocardiography and the mechanically-expanded Lotus valve. This approach should only be used in exceptional circumstances, but can be particularly relevant for patients with pre-existing chronic renal impairment, who are at increased risk of post-TAVI AKI.>.

Entities:  

Keywords:  3D trans-esophageal echocardiography; Chronic renal impairment; Trans-catheter aortic valve implantation; Zero contrast

Year:  2018        PMID: 30279933      PMCID: PMC6149618          DOI: 10.1016/j.jccase.2018.06.007

Source DB:  PubMed          Journal:  J Cardiol Cases        ISSN: 1878-5409


  4 in total

Review 1.  Acute kidney injury after transcatheter aortic valve implantation.

Authors:  Maximilian Scherner; Thorsten Wahlers
Journal:  J Thorac Dis       Date:  2015-09       Impact factor: 2.895

2.  Effect of Mechanically Expanded vs Self-Expanding Transcatheter Aortic Valve Replacement on Mortality and Major Adverse Clinical Events in High-Risk Patients With Aortic Stenosis: The REPRISE III Randomized Clinical Trial.

Authors:  Ted E Feldman; Michael J Reardon; Vivek Rajagopal; Raj R Makkar; Tanvir K Bajwa; Neal S Kleiman; Axel Linke; Dean J Kereiakes; Ron Waksman; Vinod H Thourani; Robert C Stoler; Gregory J Mishkel; David G Rizik; Vijay S Iyer; Thomas G Gleason; Didier Tchétché; Joshua D Rovin; Maurice Buchbinder; Ian T Meredith; Matthias Götberg; Henrik Bjursten; Christopher Meduri; Michael H Salinger; Dominic J Allocco; Keith D Dawkins
Journal:  JAMA       Date:  2018-01-02       Impact factor: 56.272

Review 3.  Meta-analysis of predictors of all-cause mortality after transcatheter aortic valve implantation.

Authors:  Francesca Giordana; Fabrizio D'Ascenzo; Freek Nijhoff; Claudio Moretti; Maurizio D'Amico; Giuseppe Biondi Zoccai; Jan Malte Sinning; George Nickenig; Nicolas M Van Mieghem; Adelaide Chieffo; Nicolas Dumonteil; Didier Tchetche; Israel M Barbash; Ron Waksman; Augusto D'Onofrio; Thierry Lefevre; Thomas Pilgrim; Nicolas Amabile; Pablo Codner; Ran Kornowski; Ze Yie Yong; Jan Baan; Antonio Colombo; Azeem Latib; Stefano Salizzoni; Pierluigi Omedè; Federico Conrotto; Michele La Torre; Sebastiano Marra; Mauro Rinaldi; Fiorenzo Gaita
Journal:  Am J Cardiol       Date:  2014-08-13       Impact factor: 2.778

4.  Impact of renal function on survival after transcatheter aortic valve implantation (TAVI): an analysis of the UK TAVI registry.

Authors:  Charles J Ferro; Colin D Chue; Mark A de Belder; Neil Moat; Olaf Wendler; Uday Trivedi; Peter Ludman; Jonathan N Townend
Journal:  Heart       Date:  2015-01-12       Impact factor: 5.994

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.