| Literature DB >> 30279381 |
Daehyeon Kim1, Kyemoon Baek2, Kyungho Park3.
Abstract
This study aims to improve shafts with hexagonal joints so that they will not require welding or bolts in static load tests. In order to evaluate the bearing capacity of helical piles, two sites were selected to conduct pile installation for the field test and the pile load test. For the pile load test, a static pile load test and a dynamic pile load test were carried out, and torque was measured during pile installation in a field test to compare and analyze the expected bearing capacity and thus assess the feasibility of the method for estimating the bearing capacity. The field pile load test revealed that the bearing capacity of the gravity grout pile was the same or greater than 600 kN in the static pile load test in accordance with the AC 358 code. The non-grout pile showed a bearing capacity that was the same or smaller than 600 kN, suggesting that gravity grouting is required. Moreover, the field pile load test was used to establish the bearing capacity equation considering the torque in the pile installation, and a small number of samples were used to establish the equation, which can be used as basic data.Entities:
Keywords: bearing capacity; dynamic pile load; helical pile; hexagonal joint; static pile load test
Year: 2018 PMID: 30279381 PMCID: PMC6213753 DOI: 10.3390/ma11101890
Source DB: PubMed Journal: Materials (Basel) ISSN: 1996-1944 Impact factor: 3.623
Figure 1Schematic description of (a) Individual bearing method; (b) Cylindrical shear method (Perko [3]).
Figure 2Designing hexagonal joint: (a) Hexagonal joint model; (b) Concept of load transfer.
Figure 3End of the helical pile shown in detail.
Specifications and design load of the helix plate.
| Category | Plate Diameter (Dh) | Steel Pipe Diameter (d) | Net Sectional Area of Plate | Yield Strength (MPa) | Design Load(kN) | Arm Distance (mm) |
|---|---|---|---|---|---|---|
| D1 | 350 mm | 165.2 mm | 0.075 m2 | 315 | 142 | 92.4 |
| D2 | 400 mm | 0.104 m2 | 315 | 197 | 117.4 | |
| D3 | 450 mm | 0.138 m2 | 315 | 261 | 142.4 |
Figure 4Sectional view of the Site-1 stratum.
Figure 5Sectional view of the Site-2 stratum.
Figure 6Placing pile for the field pile installation test: (a) Site-1 (15 piles); (b) Site-2 (15 piles).
Figure 7Static load test result for each site: (a) Site–1 #7; (b) Site–1 #8; (c) Site–1 #9; (d) Site–2 #7; (e) Site–2 #8; (f) Site–2 #9.
Results of the static load test for each site.
| Site | Test Location | Penetration Depth (m) | Max. Test Load (kN) | Total Settlement (mm) | Net Settlement(mm) | UltimateLoad (kN) | Allowable Bearing Capacity (kN/pile) | Grout | ||
|---|---|---|---|---|---|---|---|---|---|---|
| Safety Factor (AC 358) | Allowable Bearing Capacity | Design Load | ||||||||
| Site-1 | #7 | 12.10 | 1150.0 | 65.73 | 42.67 | 1106.6 | 2.0 | 553.3 | 600.0 | × |
| #8 | 12.10 | 1600.0 | 47.81 | 35.71 | 1600.0 | 2.0 | 800.0 | 600.0 | 100% | |
| #9 | 12.00 | 1356.0 | 59.67 | - | 1356.0 | 2.0 | 678.0 | 600.0 | 80% | |
| Site-2 | #7 | 15.90 | 1200.0 | 80.51 | 50.88 | 1108.3 | 2.0 | 554.2 | 600.0 | × |
| #8 | 16.10 | 1400.0 | 78.00 | 49.06 | 1329.3 | 2.0 | 664.7 | 600.0 | 80% | |
| #9 | 16.05 | 1350.0 | 79.51 | 50.97 | 1254.6 | 2.0 | 627.3 | 600.0 | 80% | |
Results of the dynamic pile load test for each site.
| Site | Pile No. | Test | Allowable Bearing Capacity (kN/pile) | Grout | |||
|---|---|---|---|---|---|---|---|
| Perko(F.S = 1.5) | A.P.C(F.S = 1.8) | Application(Min.) | Design Load | ||||
| Site-1 | #3 | R | 810.5 | 675.4 | 675.4 | 600.0 | O |
| #7 | R | 604.1 | 503.4 | 503.4 | 600.0 | × | |
| #8 | R | 981.5 | 817.9 | 817.9 | 600.0 | O | |
| #9 | R | 750.0 | 625.0 | 625.0 | 600.0 | O | |
| #13 | R | 743.6 | 619.7 | 619.7 | 600.0 | × | |
| Site-2 | #2 | R | 744.8 | 620.7 | 620.7 | 600.0 | O |
| #3 | R | 809.5 | 674.6 | 674.6 | 600.0 | O | |
| #7 | R | 512.2 | 426.8 | 426.8 | 600.0 | × | |
| #12 | R | 657.3 | 547.7 | 547.7 | 600.0 | × | |
| #13 | R | 676.7 | 563.9 | 563.9 | 600.0 | × | |
Note: Perko: Helical pile design and installation [3]; A.P.C: Australian Piling Code [29].
Ultimate bearing capacity according to the static load test results.
| Pile No. | End Support Layer | Grout | Ultimate Bearing Capacity (kN) |
|---|---|---|---|
| Site-1(#7) | Weathered soil | No | 1106.6 |
| Site-1(#8) | Weathered rock | Yes | At least 1600.0 |
| Site-1(#9) | Weathered soil | Yes | 1356.0 |
| Site-2(#7) | Weathered soil | No | 1108.3 |
Ratio of skin friction to end bearing capacity according to dynamic pile load test results.
| Pile No. | Allowable Bearing Capacity (kN) | Bearing Capacity Ratio | ||
|---|---|---|---|---|
| Skin Friction Capacity | End Bearing Capacity | Skin Friction Capacity | End Bearing Capacity | |
| Site-1(#7) | 13.1 | 490.4 | 2.6% | 97.4% |
| Site-1(#8) | 104.1 | 713.9 | 12.7% | 87.3% |
| Site-1(#9) | 79.7 | 545.3 | 12.7% | 87.3% |
| Site-2(#7) | 7.4 | 419.4 | 1.7% | 98.3% |
Classification of skin friction and end bearing capacity with load test results.
| Pile No. | End Support Layer | Grout | Ultimate Bearing Capacity (kN) | |
|---|---|---|---|---|
| Skin Friction Capacity | End Bearing Capacity | |||
| Site-1(#7) | Weathered soil | No | 28.8 | 1077.8 |
| Site-1(#8) | Weathered rock | Yes | 203.2 | At least 1396.8 |
| Site-1(#9) | Weathered soil | Yes | 172.2 | 1183.8 |
| Site-2(#7) | Weathered soil | No | 18.8 | 1089.5 |
Perko’s (2009) equation for calculating bearing capacity.
| Classification | Equation for Calculating Bearing Capacity | Remarks | |
|---|---|---|---|
| Ⓐ | End | qp = β × λSPT × An | ⇒ Equation for calculating end bearing capacity for each stratum |
| Cylindrical surface | qs = α × H × (π × d) | H = shaft length experiencing cylindrical surface friction (mm) | |
Characteristics depending on the installation method and experimental equations for calculating bearing capacity.
| Classification | Installation Method | Support Layer | Equation for Calculating Ultimate Bearing Capacity | ||
|---|---|---|---|---|---|
| Driven pile | Conventional piles are installed by using a drop or hydraulic hammer. | Rock bed equivalent to at least weathered rock | Ⓑ | End | qp = 300 × N × Ap |
| Cylindrical surface | qs = 2.0 × N × As | ||||
| Precast pile | A boring machine is first used to bore the ground and the pile is inserted and then driven. | Rock bed equivalent to at least weathered rock | Ⓒ | end | qp = (200–250) × N × Ap |
| Cylindrical surface | qs = (2.0–2.5) × N × As | ||||
| A boring machine is first used to mix the end with grout and the pile is inserted. | Ⓓ | End | qp = 150 × N × Ap | ||
| Cylindrical surface | qs = (2.0–2.5) × N × As | ||||
| Drilled shafts | A boring machine is first used to bore the ground, and the reinforced steel net and concrete are then laid to install the pile. | Earth and sand | Ⓔ | End | qp = 100 × N × Ap |
| Cylindrical surface | qs = (3.3–5.0) × N × As | ||||
Note: N: SPT–number of blow counts; Ap: Average area of helix plate; As: Circumference of semi-hollow shaft.
Comparison of the end bearing capacity and skin friction capacity.
| Classification | Pile No. | |||||
|---|---|---|---|---|---|---|
| 1–7 | 1–8 | 1–9 | 2–7 | |||
| Skin friction | Load test (①) | 28.8 kN | 203.2 kN | 172.2 kN | 18.8 kN | |
| Conventional equation | Ⓐ | 55.7 kN | 99.2 kN | 98.0 kN | 50.2 kN | |
| Ⓓ |
| 40.8 kN | 40.5 kN |
| ||
| Ⓔ | 144.1 kN |
|
| 102.9 kN | ||
| Ratio | Ⓐ/① | 193.4% | 48.8% | 56.9% | 267.0% | |
| Ⓓ/① | 100.0% | 20.1% | 23.5% | 109.6% | ||
| Ⓔ/① | 500.3% | 100.4% | 117.7% | 547.3% | ||
| Result of examination | Similar to result of equation D | Similar to result of equation E | Similar to result of equation E | Similar to result of equation D | ||
| End bearing capacity | Load test (①) | 1077.8 kN | At least 1,396.8 kN | 1183.8 kN | 1089.5 kN | |
| Conventional equation | Ⓐ | 869.5 kN | 830.8 kN | 830.3 kN | 874.8 kN | |
| Ⓓ | 1618.2 kN |
| 1545.3 kN | 1628.1 kN | ||
| Ⓔ |
| 1030.2 kN |
|
| ||
| Ratio | Ⓐ/① | 80.7% | 59.4% | 70.1% | 80.3% | |
| Ⓓ/① | 150.1% | 110.6% | 130.5% | 149.4% | ||
| Ⓔ/① | 100.1% | 73.8% | 87.0% | 99.6% | ||
| Result of examination | Similar to result of equation E | Similar to result of equation D | Similar to result of equation E | Similar to result of equation E | ||
| Bearing capacity equation reliability | 100.1% | 109.3% | 90.9% | 99.8% | ||
Experimental equations for calculating the bearing capacity of the helical pile.
| Classification | End Bearing Capacity (kN) | Skin Friction Capacity (kN) | Remarks | |
|---|---|---|---|---|
| Support by weathered soil + Non-grout | qp = 100 × N × Ap | qs = 1.0 × N × As | N: SPT–number of blow counts | |
| Support by weathered soil + grout | qs = 5.0 × N × As | |||
| Support by weathered rock + grout | qp = 150 × N × Ap | |||
Measured torque (T) and ultimate bearing capacity (qu).
| Pile No. | Installation Method | Final | Ultimate Bearing Capacity | Remarks |
|---|---|---|---|---|
| 1–7 | Rotary penetration | 30.9 | 1106.6 | Non-Grout |
| 1–8 | Rotary penetration + Grout | 29.5 | At least 1600 | Increased friction by gravity grout |
| 1–9 | Rotary penetration + Grout | 30.6 | 1356.0 | |
| 2–7 | Rotary penetration | 28.6 | 1108.3 | Non-Grout |
| 2–8 | Rotary penetration + Grout | 31.0 | 1329.3 | Increased friction by gravity grout |
| 2–9 | Rotary penetration + Grout | 29.8 | 1254.6 |
Figure 8Torque (T)-ultimate bearing capacity (qu).
T-qu analysis result for non-grout piles.
| Pile No. | Torque | kt | Ultimate Bearing Capacity (kN) | Bearing Capacity Ratio | |
|---|---|---|---|---|---|
| Measurement | Calculation | ||||
| Static Load Test Result | qut = T × kt | ||||
| 1–7 | 30.9 | 35.8 | 1106.6 | 1106.2 | 100% |
| 2–7 | 28.6 | 38.7 | 1108.3 | 1106.8 | 99.9% |
| Analysis result | The analysis of relation between T-qu for the non-grout piles shows that kt = 35.8 m−1 is applicable to weathered soil support piles. | ||||
T-qu analysis result for grout piles.
| Pile No. | Torque | kt | Ultimate Bearing Capacity (kN) | Bearing Capacity Ratio | |
|---|---|---|---|---|---|
| Measurement | Calculation | ||||
| Static Load Test Result | qut = T × kt | ||||
| 1–8 | 29.5 | 54.2 | At least 1600 | 1598.9 | 99.9% |
| 1–9 | 30.6 | 44.3 | 1356.0 | 1355.6 | 99.8% |
| 2–8 | 31.0 | 42.8 | 1329.3 | 1326.8 | 99.8% |
| 2–9 | 29.8 | 42.0 | 1254.6 | 1251.6 | 99.8% |
| Analysis result | The analysis of relation T-qu for the grout piles shows that kt = 54.2 m−1 is applicable to weathered rock support piles and kt = 42.0 m−1 to the weathered soil support piles. | ||||
Figure 9Results of the analysis of the relation between torque (T)–ultimate bearing capacity (qu): (a) Non-grout pile; (b) Grout pile.