Lexuan Zhong1, Stuart Batterman2, Chad W Milando3. 1. Mechanical Engineering, University of Alberta, Edmonton, AB, T6G 1H9, Canada. 2. School of Public Health, University of Michigan, 1420 Washington Heights, Ann Arbor, MI, 48109, USA. stuartb@umich.edu. 3. School of Public Health, Boston University, Boston, MA, USA.
Abstract
PURPOSE: Exposures of nail salon technicians have received attention due to the potentially toxic materials used in nail products, which include volatile organic compounds (VOCs) such as formaldehyde and methyl methacrylate (MMA). This study characterized area and personal concentrations and other indoor air parameters in 17 nail salons in fall and winter seasons in three areas of Michigan. METHODS: VOC samples were analyzed using thermal desorption, gas chromatography and mass spectroscopy, and the VOC composition of 35 nail products (e.g., polish, top coat, base coat) was measured using headspace sampling. Ventilation rates were derived using CO2 concentrations, occupancy and building information, and VOC sources were apportioned by a novel application of chemical mass balance models. RESULTS: We detected ethyl acetate, propyl acetate, butyl acetate, MMA, n-heptane and toluene in most salons, and benzene, D-limonene, formaldehyde, and ethyl methacrylate in some salons. While MMA was not measured in the consumer and professional products, and the use of pure MMA in salons has been not been permitted since the 1970s, MMA was found in air at concentrations from 100 to 36,000 µg/m3 in 15 of 17 salons; thus its use appears to be commonplace in the industry. Personal measurements, representing exposures to workers and clients, were about twice those of the area measurements for many VOCs. CONCLUSION: This study identifies the products responsible for emissions, shows the widespread presence of MMA, and documents low ventilation rates in some salons. It also demonstrates that "informal" short-term sampling approaches can evaluate chemical exposures in nail salons, providing measurements that can be used to protect a potentially susceptible and vulnerable population. Additional controls, including restrictions on the VOC compositions and improved ventilation, can reduce exposures to salon workers and clients.
PURPOSE: Exposures of nail salon technicians have received attention due to the potentially toxic materials used in nail products, which include volatile organic compounds (VOCs) such as formaldehyde and methyl methacrylate (MMA). This study characterized area and personal concentrations and other indoor air parameters in 17 nail salons in fall and winter seasons in three areas of Michigan. METHODS: VOC samples were analyzed using thermal desorption, gas chromatography and mass spectroscopy, and the VOC composition of 35 nail products (e.g., polish, top coat, base coat) was measured using headspace sampling. Ventilation rates were derived using CO2 concentrations, occupancy and building information, and VOC sources were apportioned by a novel application of chemical mass balance models. RESULTS: We detected ethyl acetate, propyl acetate, butyl acetate, MMA, n-heptane and toluene in most salons, and benzene, D-limonene, formaldehyde, and ethyl methacrylate in some salons. While MMA was not measured in the consumer and professional products, and the use of pure MMA in salons has been not been permitted since the 1970s, MMA was found in air at concentrations from 100 to 36,000 µg/m3 in 15 of 17 salons; thus its use appears to be commonplace in the industry. Personal measurements, representing exposures to workers and clients, were about twice those of the area measurements for many VOCs. CONCLUSION: This study identifies the products responsible for emissions, shows the widespread presence of MMA, and documents low ventilation rates in some salons. It also demonstrates that "informal" short-term sampling approaches can evaluate chemical exposures in nail salons, providing measurements that can be used to protect a potentially susceptible and vulnerable population. Additional controls, including restrictions on the VOC compositions and improved ventilation, can reduce exposures to salon workers and clients.
Entities:
Keywords:
Chemical exposures; Indoor air quality (IAQ); Methyl methacrylate (MMA); Occupational health; Ventilation
Authors: Diana M Ceballos; Jessica Craig; Xianqiang Fu; Chunrong Jia; David Chambers; MyDzung T Chu; Alai T Fernandez; Victoria Fruh; Zoe E Petropoulos; Joseph G Allen; Jose Vallarino; Lydia Thornburg; Thomas F Webster Journal: Indoor Air Date: 2019-05-21 Impact factor: 5.770
Authors: Denise S Tevis; Sharon R Flores; Brandon M Kenwood; Deepak Bhandari; Peyton Jacob; Jia Liu; Pawel K Lorkiewicz; Daniel J Conklin; Stephen S Hecht; Maciej L Goniewicz; Benjamin C Blount; Víctor R De Jesús Journal: Int J Hyg Environ Health Date: 2021-05-04 Impact factor: 7.401
Authors: Huan M Tran; Hanh T M Bui; Somkiat Thoumsang; Ngoc T B Ngo; Nhan P T Nguyen; Hai T M Nguyen; Son M Nguyen; Kunio Hara; Supat Wangwongwatana Journal: J Occup Health Date: 2020-01 Impact factor: 2.708
Authors: Miriam R Siegel; Carissa M Rocheleau; Kendra Broadwater; Albeliz Santiago-Colón; Candice Y Johnson; Michele L Herdt; I-Chen Chen; Christina C Lawson Journal: Occup Environ Med Date: 2021-06-30 Impact factor: 4.402