Literature DB >> 30271369

Corrigendum: Absence of Alpha-tACS Aftereffects in Darkness Reveals Importance of Taking Derivations of Stimulation Frequency and Individual Alpha Variability Into Account.

Heiko I Stecher1, Christoph S Herrmann1,2.   

Abstract

[This corrects the article DOI: 10.3389/fpsyg.2018.00984.].

Entities:  

Keywords:  EEG; aftereffect; alpha oscillations; replication; tES reliability; transcranial alternating current stimulation (tACS)

Year:  2018        PMID: 30271369      PMCID: PMC6157486          DOI: 10.3389/fpsyg.2018.01769

Source DB:  PubMed          Journal:  Front Psychol        ISSN: 1664-1078


In the original article, there was a mistake in Table 2 as published. The last parameter in the table is wrongly designated as “(β8) Group1:Block4” instead of “(β7) Group1:Block4.” The corrected Table 2 appears below.
Table 2

Decreasing tACS-sequence: result summary of linear mixed effect model.

ParameterCoef. βSE(β)tp
0) Intercept157.08617.1189.177< 0.001
1) Group1−7.0635.096−0.3020.765
2) Block215.7615.0963.0930.020
3) Block325.7785.0965.058< 0.001
4) Block429.9455.0965.876< 0.001
5) Group1:Block2−0.5126.963−0.0740.941
6) Group1:Block3−4.8376.963−0.6950.487
7) Group1:Block4−5.5256.963−7.7940.428

Coefficient estimates β for the fixed effects, standard Error SE(β), t-value t and significance level p. The model's has marginal R.

Decreasing tACS-sequence: result summary of linear mixed effect model. Coefficient estimates β for the fixed effects, standard Error SE(β), t-value t and significance level p. The model's has marginal R. In the results section, two decimal points are missing: the F-value of time x group interaction: F3, 75 = 578, is actually F3, 75 = 1.578. The p-value for T1: p = 862 is actually p = 0.862. In the same section in equations 1&2: the coefficient β4 is wrongly used twice: “β4 group1*block2,” should be “β5 group1*block2” and all subsequent “βs” numbered accordingly. A correction has been made to EEG Results, Exploratory Analysis, Paragraph 1 and Paragraph 2 and equation 1&2: Due to unexplained discrepancies between published reports and the results of our standard analysis approach, we performed an additional analysis to uncover confounding factors. Previous tACS studies in the α-range show that the power-enhancement relative to sham correlated with the negative mismatch between the stimulated frequency and true IAF (Vossen et al., 2015). Additionally it could be shown, that the inclusion of such a mismatch as a factor explains observed variance when modeling power-enhancement (Stecher et al., 2017). The large variance in the baseline α-power (see Figures 2A–C, albeit not significantly different between groups), encouraged us to test, whether baseline-power might influence the capacity for post-stimulation enhancement. For this reason, we included both the factors frequency mismatch as well as baseline power as covariates to a repeated measure ANCOVA. This did not lead to different results in the case of the decreasing sequence condition compared to sham, revealing no significant main effect of time [time (F1, 75 = 1.767, p = 0.180, η2 = 0.066)], no significant effects of the factor group (F1, 25 = 0.199, p = 0.659, η2 = 0.008), or the interaction time × group (F3, 75 = 0.578, p = 0.570, η2 = 0.023). In the case of the increasing sequence, however, the inclusion of the covariates not only revealed the above-mentioned significant main effect of time (F1, 75 = 6.471, p = 0.018, η2 = 0.206), but also a significant interaction of time × group (F3, 75 = 4.134, p = 0.009, η2 = 0.142). The interaction of time x basepower showed a trend (F3, 75 = 2.703, p = 0.051, η2 = 0.098), while the factor group (F1, 25 = 0.931, p = 0.344, η2 = 0.036) and the interaction time x mismatch did not reach significance (F3, 75 = 1.478, p = 0.227, η2 = 0.056). However, the resolution of the interaction time x group, employing post-hoc one-way ANCOVAs for every timepoint between groups, did not yield any significant differences between groups at any timepoint (T1 group: F1, 25 = 0.031, p = 0.862, η2 = 0.001; T2 group: F1, 25 = 0.148, p = 0.704, η2 = 0.006; T3 group: F1, 25 = 0.1966, p = 0.173, η2 = 0.073; T4 group: F1, 25 = 2.452, p = 0.130, η2 = 0.89; all p-values uncorrected). The authors apologize for these errors and state that this does not change the scientific conclusions of the article in any way. The original article has been updated.

Conflict of interest statement

CSH has filed a patent application on brain stimulation and received honoraria as editor from Elsevier Publishers, Amsterdam. The remaining author declares that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
  2 in total

1.  Alpha Power Increase After Transcranial Alternating Current Stimulation at Alpha Frequency (α-tACS) Reflects Plastic Changes Rather Than Entrainment.

Authors:  Alexandra Vossen; Joachim Gross; Gregor Thut
Journal:  Brain Stimul       Date:  2014-12-20       Impact factor: 8.955

2.  Ten Minutes of α-tACS and Ambient Illumination Independently Modulate EEG α-Power.

Authors:  Heiko I Stecher; Tania M Pollok; Daniel Strüber; Fabian Sobotka; Christoph S Herrmann
Journal:  Front Hum Neurosci       Date:  2017-05-18       Impact factor: 3.169

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.