Literature DB >> 30269967

Same survival but higher rate of osteolysis for metal-on-metal Ultamet versus ceramic-on-ceramic in patients undergoing primary total hip arthroplasty after 8 years of follow-up.

Yoshitoshi Higuchi1, Taisuke Seki2, Yasuhiko Takegami2, Daigo Komatsu2, Daigo Morita2, Naoki Ishiguro2.   

Abstract

BACKGROUND: To avoid wear-induced osteolysis, ceramic-on-ceramic (CoC) and metal-on-metal (MoM) bearings have been developed. At present, there are no direct material related clinical comparisons between cementless total hip arthroplasty with CoC and MoM at more than 5-year follow-up. The bearing that is more likely to prevent osteolysis is still controversial. Therefore, we performed a retrospective case control study evaluating CoC and MoM cementless THAs in order to: - compare the longevity and complications for CoC and MoM THAs at 5-10 years postoperatively; - compare the incidence of osteolysis between both type THAs; - evaluate pseudotumors in MoM THAs. HYPOTHESIS: CoC THAs will have a lower rate of osteolysis, better longevity, and better clinical outcomes than MoM THAs. PATIENTS AND METHODS: Ninety-six hips underwent CoC THAs, and 56 hips underwent MoM THA (Ultamet, Pinnacle, Depuy). Average patient age at the time of surgery was 57.1 years (range, 28 to 77 years).
RESULTS: There were no differences with regard to the Harris hip score (89.5 and 90.3 for the CoC and MoM groups, respectively). Osteolysis (9 hips, 14.3%) among MoM THAs were significantly more frequently observed compared to CoC THAs (2 hips, 2.1%). Kaplan-Meier survival at 8 years with implant loosening or revision THA as the endpoint was 98.2% (95% CI: 87.8-99.8) for CoC, and 98.6% (95% CI: 90.2-99.8) for MoM (p=0.684). There was one audible squeaking (1.0%) and no ceramic fracture among CoC THAs. Five (8.9%) hips showed pseudotumors among MoM THAs. DISCUSSION: CoC THAs had a low incidence of osteolysis. No significant difference was seen in the 8-year survival rate between implants, when using implant loosening and revision THA as endpoints. These data indicate that CoC THAs have excellent clinical and radiological outcomes, compared with MoM THAs. Ultamet MoM had a higher rate of osteolysis compared to other MoM bearings; the cup modularity (without polyethylene) and the use of 36mm heads as well as the process of production (after 2006) may play a significant role in the higher rate of osteolysis. LEVEL OF EVIDENCE: III, Case control study, case control retrospective design.
Copyright © 2018 Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  Ceramic-on-ceramic total hip arthroplasty; Metal-on-metal total hip arthroplasty; Osteolysis

Mesh:

Year:  2018        PMID: 30269967     DOI: 10.1016/j.otsr.2018.08.005

Source DB:  PubMed          Journal:  Orthop Traumatol Surg Res        ISSN: 1877-0568            Impact factor:   2.256


  2 in total

1.  Comparison of ceramic-on-ceramic bearing vs ceramic-on-highly cross-linked polyethylene-bearing surfaces in total hip arthroplasty for avascular necrosis of femoral head: a prospective cohort study with a mid-term follow-up.

Authors:  Bin Feng; Yi Ren; Shiliang Cao; Jin Lin; Jin Jin; Wenwei Qian; Xisheng Weng
Journal:  J Orthop Surg Res       Date:  2019-11-27       Impact factor: 2.359

Review 2.  Ten-year survival of ceramic-on-ceramic total hip arthroplasty in patients younger than 60 years: a systematic review and meta-analysis.

Authors:  Ihab Ibraheam El-Desouky; Albaraa Hassan Helal; Ali Mohamed Reda Mansour
Journal:  J Orthop Surg Res       Date:  2021-11-18       Impact factor: 2.359

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.