Transcatheter Tricuspid Valve Replacement for Treating Severe Tricuspid Regurgitation: Initial Experience With the NaviGate Bioprosthesis.

Lluis Asmarats1, François Dagenais1, Elisabeth Bédard1, Sergio Pasian1, Rebecca T Hahn2, José L Navia3, Josep Rodés-Cabau4.   

Abstract

Despite the growing evidence with emerging transcatheter tricuspid valve repair therapies, the experience with transcatheter tricuspid valve replacement remains sparse. We describe a case of severe tricuspid regurgitation in a 79-year-old patient deemed unsuitable for isolated tricuspid valve surgery, successfully treated with a 40-mm self-expandable NaviGate (NaviGate Cardiac Structures, Inc, Lake Forest, CA) valved stent via a transatrial approach, with excellent result and hemodynamic performance at 4 months.
Copyright © 2018 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2018        PMID: 30269838     DOI: 10.1016/j.cjca.2018.07.481

Source DB:  PubMed          Journal:  Can J Cardiol        ISSN: 0828-282X            Impact factor:   5.223


  2 in total

1.  Transcatheter Double Valve Replacement to Treat Aortic Stenosis and Severe Tricuspid Regurgitation with 3D Printing Guidance after Mechanical Mitral Valve Replacement.

Authors:  Mengen Zhai; Yu Mao; Yanyan Ma; Yang Liu; Jian Yang
Journal:  J Cardiovasc Dev Dis       Date:  2022-09-05

Review 2.  Transcatheter tricuspid valve interventions: Current status and future perspectives.

Authors:  Alberto Alperi; Marcel Almendárez; Rut Álvarez; Cesar Moris; Victor Leon; Iria Silva; Daniel Hernández-Vaquero; Isaac Pascual; Pablo Avanzas
Journal:  Front Cardiovasc Med       Date:  2022-09-14
  2 in total