Literature DB >> 30269171

Motion type and knee articular conformity influenced mid-flexion stability of a single radius knee prosthesis.

Xiao-Hong Wang1,2, Da-Yong Song3, Xiang Dong4, Toru Suguro5, Cheng-Kung Cheng6,7.   

Abstract

PURPOSE: Single radius knee implants were introduced to reduce the level of paradoxical anterior femoral translation (AFT) during mid-flexion after total knee arthroplasty. Findings from clinical and experiment studies are inconsistent, which may be due to the different loading conditions and articular conformities of the knee implants studied. The aim of this study is to analyze how variations in these two factors affect the mid-flexion stability of a single radius knee prosthesis.
METHODS: Six daily activities (walking, stair ascent, stair descent, sit-to-stand, pivot turn and crossover turn), and three articular conformity ratios (low, moderate and high) were considered. The resulting AFTs from the 18 finite element models were analyzed.
RESULTS: For low conformity knees, the worst case activity (the greatest AFT) was sit-to-stand with an AFT of 6.2 mm, while for the moderate conformity the worst case was crossover turn and pivot turn. For high conformity, all activities produced a relatively small AFT ranging from 0 mm to 1.8 mm, which more closely resembles natural knee motion. In addition, no AFT was recorded during stair ascent for all three conformities (low, moderate, high).
CONCLUSIONS: This study demonstrated that the amount of AFT is highly dependent on the activity being undertaken and the articular conformity of the knee prosthesis, and the worst case activity depends on the knee conformity. The clinical relevance of this study is that it offers valuable information towards the design of improved knee prostheses and selection of knee implants for clinical use. LEVEL OF EVIDENCE: II.

Keywords:  Anterior femoral translation (AFT); Conformity ratio; Daily activity; Mid flexion stability; Single radius knee

Mesh:

Year:  2018        PMID: 30269171     DOI: 10.1007/s00167-018-5181-2

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  3 in total

1.  Anatomic characteristics of the knee influence the risk of suffering an isolated meniscal injury and the risk factors differ between women and men.

Authors:  Wenhua Li; Jie Liang; Fei Zeng; Bomiao Lin; Chenglong Liu; Shijia Huang; Qiaolan Liu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2021-01-03       Impact factor: 4.342

2.  CORR Insights®: Does Kinematic Alignment Increase Polyethylene Wear Compared With Mechanically Aligned Components? A Wear Simulation Study.

Authors:  Cheng-Kung Cheng
Journal:  Clin Orthop Relat Res       Date:  2022-07-06       Impact factor: 4.755

3.  Moderate External Rotation of Tibial Component Generates More Natural Kinematics Than Internal Rotation After Total Knee Arthroplasty.

Authors:  Chaohua Fang; Yichao Luan; Zhiwei Wang; Long Shao; Tiebing Qu; Cheng-Kung Cheng
Journal:  Front Bioeng Biotechnol       Date:  2022-07-13