Quantitative comparison of human myocardial fiber orientations derived from DTI and polarized light imaging.

Feng Yang1, Yue-Min Zhu, Gabrielle Michalowicz, Pierre-Simon Jouk, Laurent Fanton, Magalie Viallon, Patrick Clarysse, Pierre Croisille, Yves Usson.   

Abstract

Diffusion tensor imaging (DTI) is a non-invasive technique used to obtain the 3D fiber structure of whole human hearts, for both in vivo and ex vivo cases. However, by essence, DTI does not measure directly the orientations of myocardial fibers. In contrast, polarized light imaging (PLI) allows for physical measurements of fiber orientations, but only for ex vivo case. This work aims at quantitatively comparing the myocardial fiber orientations of whole human hearts obtained from cardiac DTI with those measured by PLI. Whole human neonatal and infant hearts were first imaged using DTI. The same whole hearts were then imaged using PLI. After DTI and PLI data are registered, the orientations of fibers from the two imaging modalities were finally quantitatively compared. The results show that DTI and PLI have similar variation patterns of elevation and azimuth angles, with some differences in transmural elevation angle range. DTI itself induces an underestimation of the range of transmural elevation angles by a factor of about 25° at the basal and equatorial slices and the reduction of spatial resolution further decreases this range. PLI data exhibit a 15°  ±  5° (P  <  0.01) narrower transmural elevation angle range at apical slices than in basal or equatorial slices. This phenomenon is not observed in DTI data. In both modalities, the azimuth angle maps exhibit curved or twisting boundaries at the basal and apical slices. The experimental results globally enforce DTI as a valid imaging technique to reasonably characterize fiber orientations of the human heart noninvasively.

Entities:  

Mesh:

Year:  2018        PMID: 30265658     DOI: 10.1088/1361-6560/aae514

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  2 in total

1.  Development of a polarized hyperspectral microscope for cardiac fiber orientation imaging.

Authors:  Ximing Zhou; James Dormer; Baowei Fei
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2020-02-25

Review 2.  The Myosin Myocardial Mesh Interpreted as a Biological Analogous of Nematic Chiral Liquid Crystals.

Authors:  Pierre-Simon Jouk; Yves Usson
Journal:  J Cardiovasc Dev Dis       Date:  2021-12-11
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.