Dose area product in estimation of effective dose of the patients undergoing dental cone beam computed tomography examinations.

Ivana Kralik1, Dario Faj, Tomislav Lauc, Matko Škarica, Jelena Popić, Hrvoje Brkic.   

Abstract

OBJECTIVE: To investigate the relationship of the effective dose and dose area product (DAP) in dental cone beam computed tomography (CBCT) examinations and to propose conversion factors for estimation of effective doses of the patients using DAP. Dependence of organ doses on DAP was also investigated.
MATERIALS AND METHODS: Different exposure geometries in Cranex3Dx CBCT device were simulated using Monte Carlo simulation and computational anthropomorphic phantom. Then organ doses and effective dose for every exposure geometry was compared to DAP and analysed.
RESULTS: The effective dose in all simulated CBCT protocols and positions with 180° tube rotation ranged from 5 μSv for 50 × 50 mm2 field of view (FOV) localised on one tooth using lowest resolution to 265 μSv for the largest FOV and highest resolution. In case of 360° tube rotation the effective dose ranges from 6 to 332 μSv for the same FOV sizes and positions as well as resolutions as in 180° tube rotation.
CONCLUSIONS: Though the DAP introduces a large uncertainty in the risk measure in dental CBCT, it represents the dose and FOV size which are the most important scanning parameters affecting the dose. To decrease uncertainty in the risk measure, the effective dose has to be estimated for usual clinical positions of the FOV.

Entities:  

Year:  2018        PMID: 30264736     DOI: 10.1088/1361-6498/aae4e8

Source DB:  PubMed          Journal:  J Radiol Prot        ISSN: 0952-4746            Impact factor:   1.394


  4 in total

1.  IAEA survey of dental cone beam computed tomography practice and related patient exposure in nine Central and Eastern European countries.

Authors:  Adnan Beganović; Olivera Ciraj-Bjelac; Iliya Dyakov; Vesna Gershan; Ivana Kralik; Aleksandra Milatović; Dušan Šalát; Karapet Stepanyan; Anatoli Vladimirov; Jenia Vassileva
Journal:  Dentomaxillofac Radiol       Date:  2019-09-20       Impact factor: 2.419

Review 2.  A review of dental cone-beam CT dose conversion coefficients.

Authors:  Eugene Mah; E Russell Ritenour; Hai Yao
Journal:  Dentomaxillofac Radiol       Date:  2020-11-11       Impact factor: 2.419

3.  Minimum size and positioning of imaging field for CBCT-scans of impacted lower third molars: a retrospective study.

Authors:  Anne-Mari Ilo; Marja Ekholm; Elmira Pakbaznejad Esmaeili; Janna Waltimo-Sirén
Journal:  BMC Oral Health       Date:  2021-12-29       Impact factor: 2.757

4.  A Review of Doses for Dental Imaging in 2010-2020 and Development of a Web Dose Calculator.

Authors:  Hawon Lee; Andreu Badal
Journal:  Radiol Res Pract       Date:  2021-12-10
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.