Dispersive micro solid-phase extraction (DµSPE) with graphene oxide as adsorbent for sensitive elemental analysis of aqueous samples by laser induced breakdown spectroscopy (LIBS).

F J Ruiz1, L Ripoll2, M Hidalgo3, A Canals2.   

Abstract

In this work, the combination of dispersive micro solid-phase extraction (DµSPE) with laser-induced breakdown spectroscopy (LIBS) was evaluated for simultaneous preconcentration and detection of Zn, Cd, Mn, Ni, Cr and Pb in aqueous samples. Two adsorbent materials were tested in the microextraction step, namely graphene oxide and activated carbon. In both cases, the microextraction process consisted in the dispersion of a small quantity of adsorbent in the sample solution containing the analytes. However, while the use of activated carbon required a previous chelation of the metals, this step was avoided with the use of graphene oxide. After extraction, the analytes retained in the adsorbents were analysed by LIBS. Several experimental factors affecting the extraction of the metals (adsorbent amount, pH and extraction time) were optimized by means of the traditional univariate approach. Under optimum microextraction conditions, the analytical features of the proposed DµSPE-LIBS methods were assessed, leading to limits of detection below 100 µg kg-1 and 50 µg kg-1 with the use of activated carbon and graphene oxide, respectively, as adsorbents in the DµSPE process. Trueness evaluation of the most sensitive procedure was carried out by spike and recovery experiments in a real sample of tap water, leading to recovery values in the range 98-110%.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Dispersive micro solid-phase extraction; Graphene oxide; LIBS; Liquid samples; Trace analysis

Year:  2018        PMID: 30262046     DOI: 10.1016/j.talanta.2018.08.044

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

1.  Magnetic dispersive solid-phase extraction using a zeolite-based composite for direct electrochemical determination of lead(II) in urine using screen-printed electrodes.

Authors:  Elena Fernández; Lorena Vidal; Joaquín Silvestre-Albero; Antonio Canals
Journal:  Mikrochim Acta       Date:  2020-01-02       Impact factor: 5.833

2.  Magnetic Graphene Oxide Composite for the Microextraction and Determination of Benzophenones in Water Samples.

Authors:  Alejandro Medina; Francisco Antonio Casado-Carmona; Ángela I López-Lorente; Soledad Cárdenas
Journal:  Nanomaterials (Basel)       Date:  2020-01-18       Impact factor: 5.076

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.