Literature DB >> 30259404

Impact of Natural Variations in Freeze-Drying Parameters on Product Temperature History: Application of Quasi Steady-State Heat and Mass Transfer and Simple Statistics.

Michael J Pikal1, Paritosh Pande1, Robin Bogner2, Pooja Sane1,3, Vamsi Mudhivarthi1,4, Puneet Sharma5.   

Abstract

Inter- and intra-batch variability in heat and mass transfer during the drying phase of lyophilization is well recognized. Heat transfer variability between individual vials in the same batch arise from both different positions in the vial array and from variations in the bottom contour of the vials, both effects contributing roughly equally to variations in the effective heat transfer coefficient of the vials, Kv. Both effects can be measured in the laboratory, and variations in average Kv values as a function of vial position in the array for lab and production can be calculated by use of the simple steady-state heat and mass transfer theory. Typically, in the laboratory dryer, vials on the edge of the array, "edge vials," run 2-4°C warmer than "center vials," but differences between laboratory and manufacturing temperatures are modest. The variability in mass transfer can be assigned to major variations in ice nucleation temperature (both intra-batch and inter-batch), including major differences between laboratory and manufacturing. The net effect of all random variations, for each class of vial, can be evaluated by a simple statistical model-propagation of error, which then allows prediction of the distribution in product temperatures and drying times, and therefore prediction of percent of vials dry and percent of vials collapsed and proximity to the edge of failure for a given process. Good agreement between theoretical and experimentally determined maximum temperatures in primary drying and percent collapsed product demonstrates the calculations have useful accuracy.

Keywords:  freeze-drying; heat and mass transfer; scale-up; statistics of variability in product temperature

Mesh:

Year:  2018        PMID: 30259404     DOI: 10.1208/s12249-018-1155-4

Source DB:  PubMed          Journal:  AAPS PharmSciTech        ISSN: 1530-9932            Impact factor:   3.246


  3 in total

1.  Evaluation of Microwave Vacuum Drying as an Alternative to Freeze-Drying of Biologics and Vaccines: the Power of Simple Modeling to Identify a Mechanism for Faster Drying Times Achieved with Microwave.

Authors:  Akhilesh Bhambhani; Justin Stanbro; Daniel Roth; Elizabeth Sullivan; Morrisa Jones; Robert Evans; Jeffrey Blue
Journal:  AAPS PharmSciTech       Date:  2021-01-19       Impact factor: 3.246

2.  Pharmaceutical Quality, Team Science, and Education Themes: Observations and Commentary on a Remarkable AAPS PharmSciTech Theme Issue.

Authors:  Ajaz S Hussain; Kenneth Morris; Vadim J Gurvich
Journal:  AAPS PharmSciTech       Date:  2021-03-04       Impact factor: 3.246

3.  Temperature and Heat Transfer Control During Freeze Drying. Effect of Vial Holders and Influence of Pressure.

Authors:  Shuai Bai Palmkron; Linnea Gustavsson; Marie Wahlgren; Björn Bergensthål; Anna Millqvist Fureby
Journal:  Pharm Res       Date:  2022-08-04       Impact factor: 4.580

  3 in total