Arvid Niemöller1, Peter Jakes2, Rüdiger-A Eichel2,3, Josef Granwehr2,4.
Abstract
Conduction Electron Paramagnetic Resonance Imaging (CEPRI) is presented as a sensitive technique for mapping metallic lithium species. The method is demonstrated using different samples that are either thick or thin compared to the microwave skin depth. As a thin sample, microstructured metallic lithium deposits in a lithium-ion battery (LIB) separator were analysed, illustrating the capabilities of CEPRI by obtaining a high-resolution image with an image resolution in the micrometre range. Limitations and intricacies of the method due to non-linear effects caused by the skin effect are discussed based on images of surface patterns on thick metallic lithium samples. The lineshape of the EPR spectrum is introduced as a proxy to determine the suitability of CEPRI for the quantitative visualisation of metallic lithium deposits. The results suggest that CEPRI is particularly suited to analyse the spatial distribution of microstructured Li that forms during charging and discharging of LIB cells, including the localization of the point of failure in the case of an internal cell short circuit caused by dendrites.Entities:
Year: 2018 PMID: 30254250 PMCID: PMC6156516 DOI: 10.1038/s41598-018-32112-y
Source DB: PubMed Journal: Sci Rep ISSN: 2045-2322 Impact factor: 4.379
Figure 1First derivative CEPR signal, as measured in a field swept EPR experiment, for metallic lithium with different morphologies. The peak-to-peak linewidth is minimal for dendritic lithium with ca. 0.005 mT (green), showing a Lorentzian lineshape. For mossy lithium it increases to 0.03 mT (blue). It reaches a maximum for bulk lithium with ca. 0.15 mT (red), showing a Dysonian lineshape.
Figure 2Thick metallic lithium pieces perforated mechanically with different stamps. Top row: EPR images. Bottom row: photographs of the samples. (a) Sample with single-sided inward facing pyramidal pattern and a flat surface on the other side. (b) Two flat surfaces. (c) Lithium piece with a square cross section and a slightly inhomogeneous surface.
Figure 3EPR image of lithium dendrites grown in a glass fibre separator with a diameter of 8 mm. The appearance of dendrites is preferably found at the edge of the separator. In addition, an intense dendrite signal is found in its centre. The inset shows a photograph of the separator. The same main features are visible, yet low intensity contributions are more apparent in the EPR image due to the selectivity of the method to lithium metal only.