Literature DB >> 30252997

Repeatability of Arterial Spin Labeling MRI in Measuring Blood Perfusion in the Human Eye.

Safal Khanal1, Philip R K Turnbull1, Ehsan Vaghefi1, John R Phillips1,2.   

Abstract

BACKGROUND: Quantifying blood perfusion in ocular tissues is challenging, partly because the majority of the blood is carried by the choroid, which is difficult to visualize because it is located between the retina and sclera. PURPOSE/HYPOTHESIS: To evaluate the intra- and interday repeatability of MRI measures of chorio-retinal blood perfusion. STUDY TYPE: Prospective, cross-sectional, observational study. POPULATION: Twenty young healthy adults (six male, age: 25 ± 5 years) scanned twice within a single session repeated at the same time of day on 2 days. FIELD STRENGTH/SEQUENCE: Arterial spin labeling (ASL) MRI at 3.0T using pseudocontinuous ASL (PCASL) labeling scheme and a 3D turbo-gradient-spin-echo (TGSE) acquisition, including axial T2 -weighted structural images using a 2D turbo-spin-echo (TSE) sequence. ASSESSMENTS: Region-of-interest analysis for assessment of chorio-retinal blood perfusion. STATISTICAL TESTS: Intra- and interday repeatability of measures analyzed using intraclass correlation coefficients (ICC), Pearson's correlation analysis, paired t-tests, and Bland-Altman plots.
RESULTS: The mean chorio-retinal perfusion was 77.86 (standard deviation [SD] = 29.80) ml/100ml/min. Perfusion measurements correlated strongly within a single session (r = 0.95, 95% confidence interval [CI] [0.880-0.980], P < 0.001) and between the two sessions based on a single run (r = 0.80 [0.582-0.913], P < 0.001), and two runs (r = 0.80 [0.479-0.918], P < 0.001). There were mean differences of 2.69 [16.85 to -22.23] ml/100ml/min for intraday measures, -7.44 [27.45 to -42.32] ml/100ml/min for single-run interday measures, and 5.73 [28.71 to -40.17] ml/100ml/min for two-run interday measures, but none were significant (all P > 0.05). DATA
CONCLUSION: Quantitative ASL-MRI measurements of chorio-retinal blood perfusion showed high intra- and interday repeatability. The ASL-MRI technique provides reliable measures of chorio-retinal perfusion in vivo. LEVEL OF EVIDENCE: 1 Technical Efficacy Stage: 2 J. Magn. Reson. Imaging 2019;49:966-974.
© 2018 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  arterial spin labeling; chorio-retinal perfusion; ischemic retinal diseases; magnetic resonance imaging

Year:  2018        PMID: 30252997     DOI: 10.1002/jmri.26323

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  5 in total

1.  Hyperconnection and hyperperfusion of overlapping brain regions in patients with menstrual-related migraine: a multimodal neuroimaging study.

Authors:  Xinyu Li; Ahsan Khan; Yingying Li; Diansen Chen; Jing Yang; Haohui Zhan; Ganqin Du; Jin Xu; Wutao Lou; Raymond Kai-Yu Tong
Journal:  Neuroradiology       Date:  2021-01-03       Impact factor: 2.804

2.  Evaluation of hemodynamic changes in nonarteritic anterior ischemic optic neuropathy using multimodality imaging.

Authors:  Hongyang Li; Jiao Sun; Huihui Wang; Yanling Wang; Zhenchang Wang; Jing Li
Journal:  Quant Imaging Med Surg       Date:  2021-05

3.  Characterizing the Aging Process of the Human Eye: Tear Evaporation, Fluid Dynamics, Blood Flow, and Metabolism-Based Comparative Study.

Authors:  Md Ashiqur Rahman; Mamun Rabbani; Md Hasan Maruf; Aminul Islam; A S M Shihavuddin
Journal:  Biomed Res Int       Date:  2022-03-24       Impact factor: 3.411

4.  Incidental Magnetic Resonance Imaging Findings of Postoperative Ocular Hypotony with Choroidal Effusion after Ahmed Glaucoma Valve Implantation: A Case Report.

Authors:  Hae Min Park; Hyo Chan Jeong; Won June Lee
Journal:  Korean J Ophthalmol       Date:  2022-05-06

5.  Non-invasive Diagnosis and Prognosis Values of 3D Pseudocontinuous Arterial Spin Labeling and Optical Coherence Tomography Angiography in Proliferative Diabetic Retinopathy.

Authors:  Yanli Hou; Shuai Song; Jiao Sun; Huihui Wang; Yanling Wang; Zhenchang Wang; Jing Li; Hongyang Li
Journal:  Front Med (Lausanne)       Date:  2021-06-04
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.