Literature DB >> 30251193

Real-time surveillance of left atrial appendage thrombus during contrast computed tomography imaging for catheter ablation: THe Reliability of cOMputed tomography Beyond UltraSound in THROMBUS detection (THROMBUS) study.

Tetsuma Kawaji1, Hitomi Numamoto2, Shintaro Yamagami3, Ryu Mabuchi2, Takaaki Kitamura2, Naomi Enoki2, Koji Koizumi2, Shotaro Kanao4, Masashi Kato5, Takafumi Yokomatsu5, Satoshi Shizuta5, Shinji Miki5, Koh Ono3, Kaori Togashi4, Takeshi Kimura3.   

Abstract

Left atrial contrast computed tomography (LA-CT) as well as transesophageal echocardiography (TEE) can exclude left atrial appendage (LAA) thrombus, but is sometimes unable to evaluate LAA due to incomplete LAA filling. The aim of the current study was to validate the utility of real-time approach of LA-CT with real-time surveillance of LAA-filling defect (FD). We enrolled consecutive 894 patients with LA-CT studies acquired for catheter ablation and compared the diagnostic accuracy in demonstrating LAA-FD between conventional protocol (N = 474) and novel protocol with real-time surveillance of LAA-FD immediately after the initial scanning and, when necessary, adding delayed scanning in the supine or prone position (N = 420). Primary endpoint was severity of LAA-FD classified into the 3 groups: "Grade-0" for complete filling of contrast, "Grade-1" for incomplete filling of contrast, and "Grade-2" for complete FD of contrast. The prevalence of Grade-1 and Grade-2 FD was 17.3% and 11.2% in conventional protocol, whereas there was no patient with Grade-2 FD, and only 1 patient with Grade-1 FD after the additional scanning in novel protocol. In 5 patients with suspected LAA thrombus both by TEE and Grade-2 FD in LA-CT by the conventional protocol, ablation procedure was canceled due to diagnosis of LAA thrombus. Conversely, 4 patients with suspected LAA thrombus by TEE in novel protocol group was proved to have intact LAA by LA-CT with and without additional scanning. This novel approach with real-time surveillance improved the diagnostic accuracy of LA-CT in detecting LAA-FD, suggesting potential superiority of LA-CT over TEE in excluding LAA thrombus.

Entities:  

Keywords:  Atrial fibrillation; Contrast computed tomography; Filling defect; Left atrial appendage; Thrombus

Mesh:

Substances:

Year:  2019        PMID: 30251193     DOI: 10.1007/s11239-018-1742-y

Source DB:  PubMed          Journal:  J Thromb Thrombolysis        ISSN: 0929-5305            Impact factor:   2.300


  2 in total

1.  Novel oral anticoagulants in intracardiac thrombosis resolution: a case series.

Authors:  Mohammed Al-Sadawi; Jonathan Francois; Romy Rodriguez Ortega; Violeta Capric; Adam S Budzikowski
Journal:  Eur Heart J Case Rep       Date:  2020-08-30

2.  Cardiac Computed Tomography Versus Transesophageal Echocardiography for the Detection of Left Atrial Appendage Thrombus: A Systemic Review and Meta-Analysis.

Authors:  Shandong Yu; Heping Zhang; Hongwei Li
Journal:  J Am Heart Assoc       Date:  2021-11-19       Impact factor: 6.106

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.