| Literature DB >> 30250557 |
Abstract
The value of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) biopsy in the gastric linitis plastica (GLP) with negative malignant endoscopy biopsies was investigated. Forty-six patients with linitis plastica who had undergone EUS-FNA were retrospectively studied, and their clinicopathological data were examined. Among the 46 eligible patients, 38 cases were diagnosed clearly by EUS-FNA. There were 24 cases with lymph node metastasis in the 38 patients. Both the lymph nodes and gastric lesions were punctured by EUS-FNA in the 24 cases. We compared the diagnostic accuracy in different sites, and the results showed that the diagnostic accuracy in lymph nodes was significantly higher than that in gastric lesions (P<0.05). Among them, 16 patients underwent surgical resection, and the accuracy of the pathological diagnosis by EUS-FNA was 87.5% (14/16). The preoperative diagnostic accuracy of T and N staging by endoscopic ultrasound (EUS) were both 75%. Neither severe hemorrhage nor perforation occurred in any patient. In conclusion, EUS-FNA is a safe and effective procedure for the diagnosis of indefinite linitis plastica, and puncturing metastatic lymph nodes can improve the diagnostic accuracy.Entities:
Keywords: diagnosis; endoscopic biopsy; endoscopic ultrasonography; fine needle aspiration; gastric linitis plastica
Year: 2018 PMID: 30250557 PMCID: PMC6144711 DOI: 10.3892/ol.2018.9258
Source DB: PubMed Journal: Oncol Lett ISSN: 1792-1074 Impact factor: 2.967
Figure 1.The gastric mucosa is thick, the gastric wall is stiff, and the surface is covered with shallow ulcer.
Figure 2.Endoscopic ultrasonography of peripheral metastatic lymph nodes.
Accuracy of EUS preoperative T staging in 16 patients with linitis plastica.
| Pathologic stage | |||||
|---|---|---|---|---|---|
| EUS stage | n | T2 | T3 | T4 | Accuracy of EUS (%) |
| T2 | 10 | 8 | 2 | 0 | 80 |
| T3 | 6 | 0 | 4 | 2 | 66.7 |
| T4 | 0 | 0 | 0 | 0 | |
| Total | 16 | 8 | 6 | 2 | 75 |
EUS, endoscopic ultrasound.
Accuracy of EUS preoperative N staging in 16 patients with linitis plastica.
| Pathologic stage | ||||
|---|---|---|---|---|
| EUS stage | n | N0 | N+ | Accuracy of EUS (%) |
| N0 | 6 | 4 | 2 | 66.7 |
| N+ | 10 | 2 | 8 | 80 |
| Total | 16 | 6 | 10 | 75 |
EUS, endoscopic ultrasound.
Figure 3.Metastatic lymph node puncture guided by EUS-FNA. EUS-FNA, endoscopic ultrasound-guided fine-needle aspiration.
Figure 4.Puncture of pathological gastric wall guided by EUS-FNA. EUS-FNA, endoscopic ultrasound-guided fine-needle aspiration.
The positive rates of diagnosis in different puncture sites.
| Pathological findings of aspiration | |||
|---|---|---|---|
| Puncture sites | Positive | Negative | Diagnostic accuracy of aspiration (%) |
| Metastatic lymph node | 18 | 6 | 75 |
| Stomach walls (gastric lesions) | 13 | 11 | 54.2 |
P=0.033, <0.05.