Accuracy of phase-contrast velocimetry in systems with skewed intravoxel velocity distributions.

Antoine Vallatos1, Haitham F I Al-Mubarak2, James M Mullin2, William M Holmes3.   

Abstract

Phase contrast velocimetry (PCV) has been widely used to investigate flow properties in numerous systems. Several authors have reported errors in velocity measurements and have speculated on the sources, which have ranged from eddy current effects to acceleration artefacts. An often overlooked assumption in the theory of PCV, which may not be met in complex or unsteady flows, is that the intravoxel displacement distributions (propagators) are symmetric. Here, the effect of the higher moments of the displacement distribution (variance, skewness and kurtosis) on the accuracy of PCV is investigated experimentally and theoretically. Phase and propagator measurements are performed on tailored intravoxel distributions, achieved using a simple phantom combined with a single large voxel. Asymmetric distributions (Skewness ≠ 0) are shown to generate important phase measurement errors that lead to significant velocimetry errors. Simulations of the phase of the spin vector sum, based on experimentally measured propagators, are shown to quantitatively reproduce the relationship between measured phase and experimental parameters. These allow relating the observed velocimetry errors to a discrepancy between the average phase of intravoxel spins considered in PCV theory and the vector phase actually measured by a PFG experiment. A theoretical expression is derived for PCV velocimetry errors as a function of the moments of the displacement distribution. Positively skewed distributions result in an underestimation of the true mean velocity, while negatively skewed distributions result in an overestimation. The magnitude of these errors is shown to increase with the variance and decrease with the kurtosis of the intravoxel displacement distribution.
Copyright © 2018 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Displacement distribution; Flow; Phase contrast velocimetry; Phase-shift velocimetry; Propagator; Velocimetry; Velocity imaging

Year:  2018        PMID: 30245475     DOI: 10.1016/j.jmr.2018.09.002

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  2 in total

1.  Limits to flow detection in phase contrast MRI.

Authors:  Nathan H Williamson; Michal E Komlosh; Dan Benjamini; Peter J Basser
Journal:  J Magn Reson Open       Date:  2020-07-22

2.  Segmental differences of cervical spinal cord motion: advancing from confounders to a diagnostic tool.

Authors:  M Hupp; K Vallotton; C Brockmann; S Huwyler; J Rosner; R Sutter; M Klarhoefer; P Freund; M Farshad; A Curt
Journal:  Sci Rep       Date:  2019-05-15       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.