Literature DB >> 30238926

Should dose from small fields be limited for dose verification procedures?: uncertainty versus small field dose in VMAT treatments.

Cecile J A Wolfs1, Ans C C Swinnen, Sebastiaan M J J G Nijsten, Frank Verhaegen.   

Abstract

Over the years, radiotherapy treatments have become more complex and conformal, leading to an increased use of small field segments in volumetric modulated arc therapy (VMAT) arcs. The impact of small field dose inaccuracy on dose verification methods has not been studied yet. The aim of this work is therefore to quantify the relationship between the uncertainty of a 2D pre-treatment dose prediction model and the proportion of dose coming from small fields in VMAT arcs for a range of clinical plans. The model evaluated in this work predicts 2D portal dose images (PDIs) without a patient or phantom in the beam. The uncertainty of the model was calculated through simulation of model parameter deviations. The proportion of dose from small fields in a VMAT arc was determined by comparing a PDI with only dose from small fields with the original PDI. The uncertainty and proportion of dose from small fields were calculated for 109 VMAT arcs (41 head and neck, 33 lung, 35 prostate). The correlation was assessed with a linear regression. There is a statistically significant positive correlation between the uncertainty of the model and the proportion of dose from small fields in a VMAT arc, for each treatment site individually, as well as for all tumor sites together. The strongest relationship is found for the prostate cases. As there is a positive relationship between the uncertainty of the 2D pre-treatment dose prediction model, it may be wise to limit the dose from small fields in VMAT arcs, to avoid additional uncertainty in the dose verification process.

Entities:  

Mesh:

Year:  2018        PMID: 30238926     DOI: 10.1088/1361-6560/aae338

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Operation and calibration of the novel PTW 1600SRS detector for the verification of single isocenter stereotactic radiosurgery treatments of multiple small brain metastases.

Authors:  Esther Decabooter; Ans Cc Swinnen; Michel C Öllers; Fabian Göpfert; Frank Verhaegen
Journal:  Br J Radiol       Date:  2021-06-11       Impact factor: 3.629

2.  Limiting treatment plan complexity by applying a novel commercial tool.

Authors:  Alessandro Scaggion; Marco Fusella; Giancarmelo Agnello; Andrea Bettinelli; Nicola Pivato; Antonella Roggio; Marco A Rossato; Matteo Sepulcri; Marta Paiusco
Journal:  J Appl Clin Med Phys       Date:  2020-05-21       Impact factor: 2.102

3.  Future directions of in vivo dosimetry for external beam radiotherapy and brachytherapy.

Authors:  Frank Verhaegen; Gabriel P Fonseca; Jacob G Johansen; Luc Beaulieu; Sam Beddar; Peter Greer; Nuria Jornet; Gustavo Kertzscher; Boyd McCurdy; Ryan L Smith; Ben Mijnheer; Igor Olaciregui-Ruiz; Kari Tanderup
Journal:  Phys Imaging Radiat Oncol       Date:  2020-10-02

4.  Selection Strategy of Jaw Tracking in VMAT Planning for Lung SBRT.

Authors:  Wuji Sun; Yinghua Shi; Yu Li; Chao Ge; Xu Yang; Wenming Xia; Kunzhi Chen; Libo Wang; Lihua Dong; Huidong Wang
Journal:  Front Oncol       Date:  2022-02-08       Impact factor: 6.244

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.