Literature DB >> 30238479

Development and validation of a hydrophilic interaction ultra-high-performance liquid chromatography-tandem mass spectrometry method for rapid simultaneous determination of 19 free amino acids in rat plasma and urine.

Yongqing Wen1, Xuemei Yuan1, Feng Qin1, Longshan Zhao1, Zhili Xiong1.   

Abstract

Determination of amino acids in biofluids is a challenging task because of difficulties deriving from their high polarity and matrix interference. A simple, reliable and high-throughput hydrophilic interaction UHPLC-MS/MS method was developed and validated for the rapid simultaneous determination of 19 free amino acids in rat plasma and urine samples in this paper. Hydrophilic method with a Waters Acquity UPLC BEH Amide column (100 × 2.1 mm,1.7 μm) was used with a gradient mobile phase system of acetonitrile and water both containing 0.2% formic acid. The analysis was performed on a positive electrospray ionization mass spectrometer via multiple reaction monitoring. Samples of 10 μL plasma and 50 μL urine were spiked with three deuterated internal standards, pretreated with 250 μL acetonitrile for one-step protein precipitation and a final dilution of urine samples. Good linearities (r > 0.99) were obtained for all of the analytes with the lower limit of quantification from 0.1 to 1.2 μg/mL. The relative standard deviation of the intra-day and inter-day precisions were within 15.0% and the accuracy ranged from -12.8 to 12.7%. The hydrophilic interaction UHPLC-MS/MS method was rapid, accurate and high-throughput and exhibited better chromatography behaviors than the regular RPLC methods. It was further successfully applied to detect 19 free amino acids in biological matrix.
© 2018 John Wiley & Sons, Ltd.

Entities:  

Keywords:  19 free amino acids; determination; hydrophilic interaction ultra-high-performance liquid chromatography-tandem mass spectrometry; rat plasma; urine

Mesh:

Substances:

Year:  2018        PMID: 30238479     DOI: 10.1002/bmc.4387

Source DB:  PubMed          Journal:  Biomed Chromatogr        ISSN: 0269-3879            Impact factor:   1.902


  2 in total

1.  Molecular dynamics simulations of amino acid adsorption and transport at the acetonitrile-water-silica interface: the role of side chains.

Authors:  Yong-Peng Wang; Fei Liang; Shule Liu
Journal:  RSC Adv       Date:  2021-06-18       Impact factor: 3.361

2.  Simultaneous determination of five essential amino acids in plasma of Hyperlipidemic subjects by UPLC-MS/MS.

Authors:  Zhibin Chen; Feiyan Lin; Xuemei Ye; Yuqian Dong; Lufeng Hu; Aifang Huang
Journal:  Lipids Health Dis       Date:  2020-03-23       Impact factor: 3.876

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.