Literature DB >> 30238160

Postmortem interrogation of cardiac implantable electrical devices may clarify time and cause of death.

Lisa Riesinger1, S Fichtner2, C G Schuhmann2, H L Estner2, T Czermak2, M Graw3, F Fischer3, K Lackermair2.   

Abstract

BACKGROUND: Postmortem interrogation of cardiac implantable electrical devices (CIED) in autopsy is not routinely performed. Thus, it remains unclear whether an interrogation might clarify time and cause of death.
METHODS: Seventy of 4401 patients (1.6%) undergoing autopsy in 2014 and 2015 presented with a CIED. The explanted CIED were interrogated with respect to time and possible cause of death. Battery and lead parameters, clinical and technical alerts, and arrhythmia episodes were reviewed and afterwards correlated with the results of autopsy and clinical data.
RESULTS: Twenty-five implantable cardioverter defibrillators (ICD) and 45 pacemaker (PM) devices were analyzed. Death was classified as cardiac by autopsy in 17 of 70 patients. Accordingly, presumably lethal ventricular arrhythmias were documented in six patients (8.6%; 5 ICD, 1 PM). In two of 30 patients with unknown cause of death after autopsy (6.7%), interrogation revealed ventricular tachycardia as potential reason for decease (1 ICD, 1 PM). Postmortem CIED interrogation additionally allowed to make a statement regarding the day of death in 36 patients (51%; 13 ICD, 23 PM). This was in accordance with clinical data or the results of autopsy in nine patients (25%; 3 ICD, 6 PM) or could even clarify the time of death in six patients (16.7%; 4 ICD, 2 PM).
CONCLUSION: Interrogation of CIED revealed potentially lethal ventricular arrhythmias in 9 of 70 patients investigated and enabled valid estimation of the day of death in 15 patients. We therefore conclude that routinely performed postmortem CIED interrogation may clarify time and cause of death.

Entities:  

Keywords:  Autopsy; CIED; ICD; Implantable cardiac defibrillator; Pacemaker; Unknown death

Mesh:

Year:  2018        PMID: 30238160     DOI: 10.1007/s00414-018-1932-3

Source DB:  PubMed          Journal:  Int J Legal Med        ISSN: 0937-9827            Impact factor:   2.686


  4 in total

1.  A comment on postmortem interrogation of cardiac implantable electronic devices.

Authors:  Milos Kesek
Journal:  Int J Legal Med       Date:  2019-08-06       Impact factor: 2.686

2.  2020 APHRS/HRS expert consensus statement on the investigation of decedents with sudden unexplained death and patients with sudden cardiac arrest, and of their families.

Authors:  Martin K Stiles; Arthur A M Wilde; Dominic J Abrams; Michael J Ackerman; Christine M Albert; Elijah R Behr; Sumeet S Chugh; Martina C Cornel; Karen Gardner; Jodie Ingles; Cynthia A James; Jyh-Ming Jimmy Juang; Stefan Kääb; Elizabeth S Kaufman; Andrew D Krahn; Steven A Lubitz; Heather MacLeod; Carlos A Morillo; Koonlawee Nademanee; Vincent Probst; Elizabeth V Saarel; Luciana Sacilotto; Christopher Semsarian; Mary N Sheppard; Wataru Shimizu; Jonathan R Skinner; Jacob Tfelt-Hansen; Dao Wu Wang
Journal:  Heart Rhythm       Date:  2020-10-19       Impact factor: 6.343

3.  2020 APHRS/HRS expert consensus statement on the investigation of decedents with sudden unexplained death and patients with sudden cardiac arrest, and of their families.

Authors:  Martin K Stiles; Arthur A M Wilde; Dominic J Abrams; Michael J Ackerman; Christine M Albert; Elijah R Behr; Sumeet S Chugh; Martina C Cornel; Karen Gardner; Jodie Ingles; Cynthia A James; Jyh-Ming Jimmy Juang; Stefan Kääb; Elizabeth S Kaufman; Andrew D Krahn; Steven A Lubitz; Heather MacLeod; Carlos A Morillo; Koonlawee Nademanee; Vincent Probst; Elizabeth V Saarel; Luciana Sacilotto; Christopher Semsarian; Mary N Sheppard; Wataru Shimizu; Jonathan R Skinner; Jacob Tfelt-Hansen; Dao Wu Wang
Journal:  J Arrhythm       Date:  2021-04-08

4.  Determination of time of death by blinded post-mortem interrogation of cardiac implantable electrical devices.

Authors:  Korbinian Lackermair; Florian Fischer; Johannes Manhart; Eva Scheurer; Matthias Graw; Diana Boy; Claudia Lenz; Bonnie Hartrampf; Antonia Kellnar; Lauren Sams; Heidi Estner; Stephanie Fichtner
Journal:  Sci Rep       Date:  2022-05-17       Impact factor: 4.379

  4 in total